Causes: - The detected temperature of the thermistor does not reach 35 deg C within approx. 1.5 sec of the heater being turned on. - The detected temperature of the thermistor is 100 deg C or lower in standby mode.
Remedy: - Check connectors on the fixing film unit. - Replace the fixing film unit. - Replace the engine controller PCB.
Causes: - After the heater is turned on, the detected temperature of the thermistor is 100 deg C or lower at the time of printing after reaching 50 deg C. - After the heater is turned on, the detected temperature of the thermistor is 55 deg C or lower at paper intervals or in cleaning mode after reaching 50 deg C.
Remedy: - Check connectors on the fixing film unit. - Replace the fixing film unit. - Replace the engine controller PCB.
Causes: - At startup of the scanner, /BDI signal cannot be detected within 0.1 sec after forced acceleration of the scanner motor. - At startup of the scanner during activation of the scanner motor, the motor rotation exceeds the range of specified value (98.3 to 102.1%). - After startup of the scanner is correctly completed, /BDI signal exceeds the specified cycle 10 times consecutively.
Remedy: Check connectors on the scanner unit - Replace the scanner unit. - Replace the engine controller PCB