Causes: When heater temperature control is under way during initial rotation, the reading of the main thermistor fails to reach the target temperature within 80 sec. Cause The fixing film unit is faulty. The DC controller PCB is faulty.
Remedy: - Replace the fixing film unit. - Replace the DC controller PCB.
Code: E000-1
Description: Fixing fault
Causes: When the heater is on, the heater drive current level is below a specific value for as long as 5 waves of the zero-cross signal. Cause The fixing film unit is faulty. The DC controller PCB is faulty.
Remedy: - Replace the fixing film unit. - Replace the DC controller PCB.
Code: E001-0
Description: Fixing error high temperature
Causes: The reading of the main thermistor is 240 deg C or more continuously for 0.1 sec or more. Cause The main thermistor is faulty. The DC controller PCB is faulty.
Remedy: - Replace the fixing film unit. - Replace the DC controller PCB.
Code: E001-1
Description: Fixing error high temperature
Causes: The reading of the sub thermistor is 300 deg C or more continuously for 0.5 sec or more. Cause The sub thermistor is faulty. The DC controller PCB is faulty.
Remedy: - Replace the fixing film unit. - Replace the DC controller PCB.
Code: E003-0
Description: Fixing low temperature
Causes: The reading of the main thermistor fails to exceed 40 deg C within 4 sec after the start of the heater during the wait period. While heater temperature control is under way during initial rotation, the reading of the main thermistor is 70 deg C or lower continuously for 4 sec or more. While heater temperature control is under way during a standby state, the reading of the main thermistor is 50 deg C or less continuously for 0.5 or more. While heater temperature control is under way during printing, the reading of the main thermistor is 80 deg C or less continuously for 0.5 sec or more. While heater temperature control is under way during printing, the reading of the main thermistor is 40 deg C or lower than the target temperature continuously for 0.5 sec or more. The reading of any of the sub thermistors (1, 2, 3) fails to exceed 60 deg C or more within 4 sec after the start of the heater during the wait period. Cause The main thermistor is faulty. The DC controller PCB is faulty. The connector has
Remedy: - Replace the fixing film unit. - Replace the DC controller PCB.
Code: E003-1
Description: Fixing low temperature
Causes: The reading of any of the sub thermistors (1, 2, 3) fails to exceed 60 deg C within 4 sec after the start of the heater during the wait period. Cause The sub thermistor is faulty. The DC controller PCB is faulty. The connector has poor contact, or the harness is faulty.
Remedy: - Replace the fixing film unit. - Replace the DC controller PCB.
Causes: The zero-cross signal is not detected for a specific period of time or more. Cause The fixing control circuit is faulty.
Remedy: - Replace the DC controller PCB.
Code: E012-0
Description: Main Motor Error
Causes: The main motor fails to reach its normal rotation speed within 1.2 sec after it has started. Cause The main motor is faulty. The DC controller PCB is faulty.
Remedy: - Replace the main motor. - Replace the DC controller PCB.