Code: E602-1312

Description: Error in Main Controller memory
Causes: Device access error
Remedy: Execute the following procedures. 1. Turn OFF and then ON the power. 2. Download the /APL_CDS firmware again by Updater.

Code: E602-1313

Description: Error in Main Controller memory
Causes: Device access error
Remedy: Execute the following procedures. 1. Turn OFF and then ON the power. 2. Download the /APL_CDS firmware again by Updater.

Code: E602-1602

Description: Error in Main Controller memory
Causes: File system initialization error
Remedy: Execute the following procedures. 1. Turn OFF and then ON the power. 2. Download the /APL_CDS firmware again by Updater.

Code: E602-1612

Description: Error in Main Controller memory
Causes: Device access error
Remedy: Execute the following procedures. 1. Turn OFF and then ON the power. 2. Download the /APL_CDS firmware again by Updater.

Code: E602-1613

Description: Error in Main Controller memory
Causes: Device access error
Remedy: Execute the following procedures. 1. Turn OFF and then ON the power. 2. Download the /APL_CDS firmware again by Updater.

Code: E604-0000

Description: Insufficient memory capacity
Causes: Insufficient memory capacity
Remedy: - Remove and then install the additional memory. - Replace the additional memory with a correct one. - Turn OFF and then ON the power. - Replace the Controller PCB.

Code: E604-0001

Description: Insufficient memory capacity
Causes: Failed to allocate the memory required to start PDL.
Remedy: - Remove and then install the additional memory. - Replace the additional memory with a correct one. - Turn OFF and then ON the power. - Replace the Controller PCB.

Code: E616-0001

Description: Error in MEAP application
Causes: MEAP application was deleted by auto recovery at restart after E602-11XX.
Remedy: Initialize MEAP area in the flash memory with the following procedures, and install MEAP application again. 1. Initialize the MEAP area. Service Mode > FUNCTION GR. > MEAP > MEAP FUNCTION > ON 2. Install MEAP application again.