Code: E066-0000

Description: Environment sensor abnormality
Environment sensor abnormality
Causes: Environment sensor defect, DC controller PCB defect
Remedy: • Check the connector of the environment sensor, DC controller PCB. • Replace environment sensor • Replace DC controller PCB

Code: E070-0000

Description: ITB/TOP sensor failed
ITB/TOP sensor failed.
Causes: ITB/TOP sensor defect, DC controller PCB defect
Remedy: • Check the connector of the ITB unit, DC controller PCB. • Replace ITB unit • Replace DC controller PCB

Code: E100-0000

Description: Scanner unit, laser unit, BD abnormality.
Yellow optical assembly failure.
Causes: Laser scanner defect, DC controller PCB defect
Remedy: • Check the connector of the laser scanner unit, DC controller PCB. • Replace laser scanner unit • Replace DC controller PCB

Code: E100-0001

Description: Scanner unit, laser unit, BD abnormality.
Magenta optical assembly failure.
Causes: Laser scanner defect, DC controller PCB defect
Remedy: • Check the connector of the laser scanner unit, DC controller PCB. • Replace laser scanner unit • Replace DC controller PCB

Code: E100-0002

Description: Scanner unit, laser unit, BD abnormality.
Cyan optical assembly failure.
Causes: Laser scanner defect, DC controller PCB defect
Remedy: • Check the connector of the laser scanner unit, DC controller PCB. • Replace laser scanner unit • Replace DC controller PCB

Code: E100-0003

Description: Scanner unit, laser unit, BD abnormality.
Black optical assembly failure.
Causes: Laser scanner defect, DC controller PCB defect
Remedy: • Check the connector of the laser scanner unit, DC controller PCB. • Replace laser scanner unit • Replace DC controller PCB

Code: E110-0000

Description: BD correction control failure
The machine does not change to the scanner ready status, after starting BD control.
Causes: Laser scanner unit defect, DC controller PCB defect
Remedy: • Replace the laser scanner unit • Replace DC controller PCB

Code: E196-0000

Description: DCON ROM abnormality
DC controller PCB ROM update failed.
Causes:
Remedy: • Replace DC controller PCB • Replace Main controller PCB