Remedy: - Turn OFF and then ON the main power. If the error persists, obtain the following information and contact the department in charge of quality management. - Output STATUS PRINT/ P-PRINT. - Collect Sublog - Collect information on conditions to reproduce the error - Obtain user's print data (binary data)
Remedy: - Turn OFF and then ON the main power. If the error persists, obtain the following information and contact the department in charge of quality management. - Output STATUS PRINT/ P-PRINT. - Collect Sublog - Collect information on conditions to reproduce the error - Obtain user's print data (binary data)
Remedy: - Turn OFF and then ON the main power. If the error persists, obtain the following information and contact the department in charge of quality management. - Output STATUS PRINT/ P-PRINT. - Collect Sublog - Collect information on conditions to reproduce the error - Obtain user's print data (binary data)
Causes: Temperature of the Main Thermistor did not become the specified temperature although the specified time had passed.
Remedy: 1. Check the drawer connector between the Fixing Assembly and the Fixing Power Supply Unit. 2. Replace the Fixing Assembly. 3. Replace the Fixing Power Supply Unit
Causes: The Main Thermistor detected a temperature higher than the specified temperature.
Remedy: 1. Check the drawer connector between the Fixing Assembly and the Fixing Power Supply Unit. 2. Replace the Fixing Assembly. 3. Replace the Fixing Power Supply Unit.
Causes: The Sub Thermistor 1 detected a temperature higher than the specified temperature.
Remedy: 1. Check the drawer connector between the Fixing Assembly and the Fixing Power Supply Unit. 2. Replace the Fixing Assembly. 3. Replace the Fixing Power Supply Unit.
Causes: The Sub Thermistor 2 detected a temperature higher than the specified temperature.
Remedy: 1. Check the drawer connector between the Fixing Assembly and the Fixing Power Supply Unit. 2. Replace the Fixing Assembly. 3. Replace the Fixing Power Supply Unit.
Description: Abnormally low fixing temperature detection 1
Causes: Temperature of the Main Thermistor was lower than the specified temperature when the heater was ON.
Remedy: 1. Check the drawer connector between the Fixing Assembly and the Fixing Power Supply Unit. 2. Replace the Fixing Assembly. 3. Replace the Fixing Power Supply Unit.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.