Mã lỗi Canon LBP7750Cdn
Code:
Tất cả lỗi (67)
E000-0000
E001-0000
E001-0001
E001-0004
E003-0000
E003-0001
E003-0004
E004-0000
E012-0002
E012-0003
E012-0004
E012-0005
E012-0006
E012-0007
E012-0008
E012-0009
E014-0000
E014-0001
E015-0000
E015-0001
E015-0002
E020-0000
E066-0000
E06F-0068
E078-0001
E100-0000
E100-0001
E100-0002
E100-0003
E100-0004
E110-0000
E110-0001
E196-0000
E196-0001
E198-0000
E602-0001
E602-0002
E602-0003
E602-0006
E602-0007
E604-0000
E730-100A
E730-C000
E730-C001
E733-0001
E733-0004
E733-0005
E733-0006
E740-0002
E740-0004
E744-0800
E744-0900
E744-1000
E748-4000
E748-4020
E760-0000
E804-0000
E805-0003
E805-0006
E806-0001
E808-0001
E825-0000
E825-0001
E825-0002
E825-0003
E825-0004
E840-0000
Description: Fixing startup failure
Causes: The detection temperature of the main thermistor did not increase after start of the power distribution to the heater.
Remedy: Replace the fixing assembly. Replace the DC controller PCB
Description: Abnormal high temperature in fixing
Causes: The main thermistor detected a temperature of higher than 255 degree C.
Remedy: Replace the fixing assembly. Replace the DC controller PCB.
Description: Abnormal high temperature in fixing
Causes: The sub thermistor detected a temperature of higher than 290 degree C.
Remedy: Replace the fixing assembly. Replace the DC controller PCB.
Description: Abnormal high temperature in fixing
Causes: The sub thermistor 2 detected a temperature exceeding a specified temperature
Remedy: Replace the fixing assembly. Replace the DC controller PCB.
Description: Abnormal low temperature in fixing
Causes: The main thermistor detected a temperature of lower than 120 degree C for more than 1 second when 20 seconds elapsed after start of the power distribution to the heater.
Remedy: Replace the fixing assembly. Replace the DC controller PCB.
Description: Abnormal low temperature in fixing
Causes: The sub thermistor detected a temperature of lower than 80 degree C for more than 2 seconds when 20 seconds elapsed after start of the power distribution to the heater.
Remedy: Replace the fixing assembly. Replace the DC controller PCB.
Description: Abnormal low temperature in fixing
Causes: The sub thermistor 2 detected a temperature lower than a specified temperature.
Remedy: Replace the fixing assembly. Replace the DC controller PCB.
Description: Fixing assembly drive circuit failure
Causes: 43 to 57Hz could not be detected continuously for more than 5 seconds when zero cross detection started.
Remedy: Check the contact of the connector between the fixing assembly and the low-voltage power supply PCB. Replace the low-voltage power supply PCB.