Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Canon MF247dw — Trang 2/5

Code: 0018H

Description: Door Open Jam
Remedy:

Code: 001CH

Description: Wrap Jam
Remedy:

Code: 0020H

Description: Reversal Delay Jam
Remedy:

Code: 0021H

Description: Reversal Stationary Jam
Remedy:

Code: 0071H

Description: Timing Error
Remedy:

Code: 0094H

Description: Initial Stationary
Remedy:

Code: 0095H

Description: Pickup NG
Remedy:

Code: E000 0000

Description: Fixing Assembly does not start up within specified time.
Remedy: When the same error repeatedly occurs after several times of turning the power OFF/ON, execute the following remedies. 1. Check that the heater resistance measured between 1PIN and 2PIN of the cable (J101) on the DC Controller Board is in the following range. Replace the Fixing Assembly when the resistance value is abnormal. [1] 120 V machine - Heater resistance: 16.0 Ù ±7% [2] 230 V machines - Heater resistance: 53.8 Ù ±7% 2. Check the connection of connector (J101) on the DC Controller Board. 3. Check the connection of connector (J552) on DC Controller Board. 4. Replace the Fixing Assembly. 5. Replace the DC Controller Board.