Description: Abnormally low temperature (detected by main thermistor)
After the temperature detected by the main thermistor has reached the specified value, it does not reach the specified value during initial rotation.
Remedy: - Check the connector of the fixing film unit. - Replace the fixing film unit. - Replace the DC controller PCB.
Description: Abnormally low temperature (detected by sub thermistor)
After the temperature detected by the sub thermistor has reached the specified value, it does not reach the specified value during initial rotation.
Remedy: - Check the connector of the fixing film unit. - Replace the fixing film unit. - Replace the DC controller PCB.
Description: Waster toner full detection sensor is faulty.
The waste toner full state was detected continuously for five or more seconds while the main motor was turning.
Remedy: - Check the connector of the waster toner full sensor. - Replace the waste toner full sensor. - Replace the DC controller PCB.
Description: Erroneous connection to duplex unit
Disconnection of the duplex unit was detected after power-on, detection of normal connection to the duplex unit, and start of communication.
Remedy: - Check the connectors of the duplex unit and DC controller PCB. - Replace the duplex controller PCB. - Replace the DC controller PCB.