Description: Error in the fixing assembly start-up.
Causes: Insufficient temperature rise detected by thermistor even after applying bias to the heater Cause: disconnected main thermistor / fixing heater, problem in DC controller PCB
Remedy: • Check connectors of fixing assembly, DC controller PCB, fixing power supply unit, etc. • Replace fixing film units • Replace fixing power supply units • Replace DC controller PCBs
Description: Abnormally high temperature detected in fixing assembly
Causes: Abnormally high temperature detected by main thermistor Cause: problem in main thermistor / DC controller
Remedy: • Check connectors of fixing assembly / DC controller PCB • Replace fixing film units • Replace fixing power supply units • Replace DC controller PCB
Description: Abnormally high temperature detected in fixing assembly
Causes: Abnormally high temperature detected by sub thermistor (sub thermistor triggered) Cause: problem in sub thermistor / DC controller PCB
Remedy: • Check connectors of fixing assembly / DC controller PCB • Replace fixing film units • Replace fixing power supply units • Replace DC controller PCBs
Description: Abnormally low temperature detected in fixing assembly
Causes: Temperature drop detected by main thermistor after attaining the target temperature Cause: problem in fixing power supply unit, disconnection of main thermistor, problem in DC controller PCB
Remedy: • Check connectors of fixing assembly / DC controller PC • Replace fixing film/fixing power supply units • Replace DC controller PCBs
Description: Abnormally low temperature detected in fixing assembly
Causes: Temperature drop detected by sub thermistor after attaining the target temperature (sub thermistor triggered) Cause: problem in fixing power supply unit, disconnection of sub thermistor, problem in DC controller PCB
Remedy: • Check connectors of fixing assembly / DC controller PCB • Replace fixing film units • Replace fixing power supply units • Replace DC controller PCBs
Causes: Error in attaining the target ITB motor rotation detected based on ITB motor speed detection signal after ITB motor is actuated. Cause: problem in ITB motor / DC controller PCB
Remedy: • Check connectors of ITB motor / DC controller PCB • Replace ITB motors • Replace DC controller PCBs
Causes: Error in ITB motor rotation after attaining the target rotation detected based on ITB motor speed detection signal. Cause: problem in ITB motor / DC controller PCB
Remedy: • Check connectors of ITB motor / DC controller PCB • Replace ITB motors • Replace DC controller PCBs
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.