Mã lỗi Canon Satera MF9220Cdn — Trang 5/7
Code:
Tất cả lỗi (53)
E000-0000
E001-0000
E001-0001
E003-0000
E003-0001
E004-0000
E012-0000
E012-0001
E012-0002
E012-0003
E012-0004
E012-0005
E012-0006
E012-0007
E012-0008
E012-0009
E014-0000
E014-0001
E015-0000
E020-0000
E024-0000
E024-0001
E024-0002
E024-0003
E066-0000
E078-0000
E100-0000
E100-0001
E100-0002
E100-0003
E100-0004
E100-0005
E194-0000
E196-0001
E197-0000
E198-0000
E202-0001
E202-0002
E225-0000
E248-0001
E248-0002
E248-0003
E248-0004
E351-0000
E719-0000
E719-0002
E744-0001
E744-0002
E744-0003
E744-0004
E804-0000
E805-0005
E840-0000
Description: Error in CPR sensor
Causes: Cannot detect color displacement detection pattern, detected results fall outside the acceptable range. Cause Dirty color displacement detection sensor, color displacement detection sensor fault, DC controller PCB assembly fault, toner cartridge fault.
Remedy: - Replace ETB unit - Terminal assembly fault (check on every contact between the terminals of each color and the high voltage PCB assembly) - Replace DC controller PCB - Replace toner cartridge
Description: Error in DCON ROM
Causes: Updating the ROM on the DC controller PCB assembly has been failed.
Remedy: - Replace DC controller PCB
Description: Engine communication error
Causes: Internal communication error
Remedy: - Replace DC controller PCB - Replace video controller PCB
Description: DC controller memory malfunction
Causes: DC controller memory malfunction. Cause DC controller PCB assembly fault.
Remedy: - Replace DC controller PCB assembly
Description: Reader HP sensor fault
Causes: Reader HP outward fault The CCD unit moves backward, but does not move to the home position.
Remedy: - Replace reader HP sensor. - Replace reader motor sensor. - Replace reader unit.
Description: Reader HP sensor fault
Causes: Reader HP homeward fault - Replace reader unit. The CCD unit moves forward, but does not move to the home position.
Remedy: - Replace reader HP sensor. - Replace reader motor sensor. - Replace reader unit.
Description: Error in light intensity of the lamp
Causes: Decrease of light intensity of the lamp.
Remedy: Replace reader unit.
Description: EEPROM access error
Causes: Error at EEPROM power-on EEPROM data cannot be read at power-on.
Remedy: Replace reader unit.