Description: Air leaks
The Pressure pump has air leaks.
Remedy: Check that the pressure tube is properly connected. Reconnect the tube correctly if not. Replace the pressure pump (PURESSURE, PUMP, ASSY).
Code: 1403
Description: Pressure reducing error
The pressure cannot be reduced.
Remedy: Replace the pressure pump (PURESSURE, PUMP, ASSY).
Code: 1404
Description: Pump movement cycle over error
The Pressure pump performed its movement cycle a predetermined number of times (60 cycles), but the pressure does not reach the specified level due to a malfunction of the pump, sensor or motor. Because of air leaks, the specified pressure cannot be obtained. Air is leaking through a gap between the ink cartridge and the ink cartridge holder due to an obstruction between them.
Remedy: Replace the pressure pump (PURESSURE, PUMP, ASSY). Replace the ink cartridge. Check junction of the ink cartridge and the ink cartridge holder, and remove any obstruction between them if any.
Code: 1410
Description: Drive time monitor time-out (PUMP)
The Pump motor run away out of control.
Remedy: Turn the printer power On and Off. Replace the main board (BOARD ASSY., MAIN).
Code: 1425
Description: CSIC communication time-out
The printer cannot read/write data from/into the CSIC of the ink cartridge or the maintenance cartridge.
Remedy: Check the connection between the CSIC and the main board and fix any abnormality. Replace the ink cartridge or the maintenance cartridge. Replace the main board (BOARD ASSY., MAIN).
Code: 142D
Description: Pump cap unit life error
The pump counter has reached its upper limit.
Remedy: Replace the Pump Cap Unit (PUMP, CAP, ASSY), and reset the counter using the Adjustment Program.
Code: 1430
Description: Holder ink pad error
The ink cartridge installation/removal counter has reached the specified limit.
Remedy: Replace the ink pad in the holder (POROUS PAD,TRAY,INK EJECT) and reset the counter using the Adjustment Program.
Code: 1431
Description: Ink selector error
The number of drives of the Ink Selector has reached the specified limit.
Remedy: Replace the Ink Selector (INK, SYSTEM, ASSY.) and reset the counter using the Adjustment Program.