Description: Ink selector drive timeover
Changing the ink path by the Ink Selector cannot be completed during a predetermined time period due to a malfunction of the Ink Selector (its sensor or motor).
Remedy: Replace the Ink Selector (INK, SYSTEM, ASSY.) and reset the counter using the Adjustment Program.
Code: 1434
Description: Ink cover unlock error
The cartridge cover cannot open due to an obstruction on the top of it. The ink cover open sensor is broken and cannot detect an open/ close status of the cover. The ink cover solenoid is broken and cannot unlock the cover.
Remedy: Remove any obstruction on the cover. Replace the ink cover Open sensor. Replace the ink cover solenoid.
Code: 1501
Description: Release phase detection error
The release roller position sensor cannot detect the actuator after the release motor has driven a predetermined number of steps.
Remedy: Replace the release motor (MOTOR, RELEASE, ASSY). Replace the release roller position sensor (Release Sensor).
Code: 1502
Description: Drive time monitor time-out
The condition to stop the release motor are not satisfied when the release motor has driven for a predetermined time period.
Remedy: Replace the release roller position sensor (Release Sensor). Replace the release motor (MOTOR, RELEASE, ASSY).
Code: 150C
Description: PF phase detection error
The APG sensor cannot detect the origin point when the APG motor has driven for a predetermined time period.
Remedy: Replace the APG motor (MOTOR, ASSY, APG). Replace the APG sensor.
Code: 1511
Description: Drive time monitor time-out (APG)
The APG motor run away out of control.
Remedy: Turn the printer power On and Off. Replace the main board (BOARD ASSY., MAIN).
Code: 1520
Description: Drive time monitor time-out (CR)
The CR motor run away out of control.
Remedy: Turn the printer power On and Off. Replace the main board (BOARD ASSY., MAIN).
Code: 1531
Description: ASF phase detection error
A status detected by the ASF sensor does not change when the ASF motor has driven for a predetermined time period.
Remedy: Replace the ASF motor (MOTOR, ASSY, ASF). Replace the ASF sensor.