Description: Release motor phase detection error
When releasing the driven roller, the Roller Release HP Sensor cannot detect the change of status.
Remedy: Check the installation status of the Roller Release HP Sensor. Check the connection between the Roller Release HP Sensor and the Main Board Assy. Replace the Roller Release HP Sensor.
Description: PG phase detection error
During PG operation, the PG HP Sensor cannot detect the change of status.
Remedy: Check the installation status of the PG HP Sensor. Check the connection between the PG HP Sensor and the Main Board Assy. Replace the PG HP Sensor.
Description: Overload error
The electric current flowing when driving the motor is irregularly large. • Encoder cable is damaged. • Motor cable is damaged. • Irregular load • Encoder failure • Motor failure
Remedy: Check if there is some foreign material causing extra load between the APG Motor and the carriage unit. Check the connection between the APG Motor Sensor and the Main Board Assy. Replace the APG Motor.
Description: Over speed error
Detects that it is being driven at an irregularly faster speed than the specified value just before stopping. • Irregular load • Encoder failure
Description: Reversing error
Detects that it is being driven in the opposite direction to the specified driving direction. • The polarity of encoder cable is opposite. • The polarity of motor cable is opposite. • Encoder failure • Irregular load
Remedy: Check the connection between the APG Motor Sensor and the Main Board Assy. Replace the APG Motor.
Description: Velocity deviation error
Detects that it is being driven at an irregularly faster speed than the specified value. • Irregular load • Encoder failure • Motor driver failure • Motor failure
Remedy: Replace the APG Motor. Replace the Main Board Assy.
Description: Lock error
Detects that it is being driven at an irregularly slower speed than the specified value. • Encoder cable is damaged. • Motor cable is damaged. • Irregular load • Encoder failure • Motor failure
Remedy: Check if there is some foreign material causing extra load between the APG Motor and the carriage unit. Check the connection between the APG Motor Sensor and the Main Board Assy. Replace the APG Motor.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.