Description: AID voltage error
Due to the leak of AID current, the specified voltage cannot be achieved.
Remedy: Check the flushing box and around it, and remove ink and dust if attached on it. (Electric current may leak through the accumulated ink or dust.) Replace the AID Board. Replace the Ink System Unit.
Description: RTC Access T/O error
The RTC circuit on the Main Board Assy malfunctions.
Remedy: 1. Turn the power off and remove the RTC backup battery. 2. After several seconds, re-attach the battery and turn the power back on. 3. If the printer recovers from the error, set the date and time using the Service Program.
Description: Thermistor error
The Head FFC is not connected correctly. The thermistor detects a temperature out of the specification. The thermistor is broken.
Description: Head error
The drive circuit in the Printhead is damaged due to a slant connection of the Head FFC, etc., or the fuse of the Main Board Assy may has blown because of such a wrong connection.
Remedy: 1. Check the connection of the Head FFC to the Sub Board Assy, and correct it if there is a slant connection or the cable is disconnected. If any connection terminal of the Head FFC is damaged, replace it with a new one. 2. Replace the Printhead. 3. If the printer does not recover from the error after trying 1 and 2., replace the Main Board Assy. (The fuse of the Main Board Assy may have blown due to a slant connection of the Head FFC.)
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.