Code :
  • Code: 54.16
  • Display: 54.XX Error
  • Description: An error has occurred with one of the tonerlevel sensors.
    Magenta
  • Remedy: 1. Make sure that connector J1020 on the DC controller is seated correctly. 2. Replace the DC controller PCA.
  • Code: 54.17
  • Display: 54.XX Error
  • Description: An error has occurred with one of the tonerlevel sensors.
    Cyan
  • Remedy: 1. Make sure that connector J1020 on the DC controller is seated correctly. 2. Replace the DC controller PCA.
  • Code: 54.18
  • Display: 54.XX Error
  • Description: An error has occurred with one of the tonerlevel sensors.
    Black
  • Remedy: 1. Make sure that connector J1020 on the DC controller is seated correctly. 2. Replace the DC controller PCA.
  • Code: 55.X
  • Display: 55.X Error Turn off then on
  • Description: A communication error between the DC controller and the formatter has occurred.
  • Remedy: 1. Turn the printer off. 2. Reconnect the connector between the DC controller and the formatter. 3. Replace the DC controller PCA.
  • Code: 56.XX
  • Display: 56.XX Error
  • Description: One of the trays is installed incorrectly.
  • Remedy: Make sure tray 2 and optional tray 3 are completely closed.
  • Code: 57.XX
  • Display: 57.XX Error Turn off then on
  • Description: A printer fan error has occurred.
  • Remedy: 1. Check that connector J1008 on the DC controller is seated correctly. 2. Replace the fan. 3. Replace the DC controller PCA.
  • Code: 59.30
  • Display: 59.30 Error
  • Description: An error occurred with the fuser motor during startup or rotation.
  • Remedy: 1. Turn the printer off then on. 2. Check that connectors J5008 on the fuser motor and J213 on the driver PCA are seated correctly. 3. Replace the fuser. 4. Replace the fuser drive motor.
  • Code: 59.40
  • Display: 59.40 Error
  • Description: An error occurred with the fuser motor during startup or rotation.
  • Remedy: 1. Turn the printer off then on. 2. Check that connectors J5008 on the fuser motor and J213 on the driver PCA are seated correctly. 3. Replace the fuser. 4. Replace the fuser drive motor.