Description: The device has experienced an internal sensor error (most likely, the top-of-page sensor).
Remedy: Turn off the power by using the power switch, wait at least 30 seconds, and then turn on the power and wait for the device to initialize. If the error persists, check the top-of-page sensor. If the error persists, replace the DC controller.
Description: The device has experienced an internal hardware error.
Remedy: Turn off the device, and then disconnect the power cord. Remove the fuser, and then wait at least 20 minutes. Reinstall the fuser, turn on the device, and then wait for the device to initialize. CAUTION The parts on the internal surface of the fuser are very hot. To avoid burning yourself, do not touch those parts. Perform the heating-element check. If the error persists, replace the fuser assembly. See Replacing the fuser assembly. If, after replacing the fuser assembly, the error persists, replace the power supply.
Description: The device has experienced an internal hardware error.
Remedy: switch, wait at least 30 seconds, and then turn on the power and wait for the device to initialize. If the error persists, replace the laser/ scanner assembly.
Description: The device has experienced an internal hardware error.
Remedy: Turn off the power by using the power switch, wait at least 30 seconds, and then turn on the power and wait for the device to initialize. If the error persists, replace the scanning assembly.
Description: The device has experienced an internal hardware error.
Carousel rotation error
Remedy: Turn off the power by using the power switch, wait at least 30 seconds, and then turn on the power and wait for the device to initialize.
Replace the carousel drive motor. If the error persists, replace the DC controller. If the error still persists, inspect or replace the engaging detection flag.
Description: The device has experienced an internal hardware error.
DC controller Memory Error
Remedy: Turn off the power by using the power switch, wait at least 30 seconds, and then turn on the power and wait for the device to initialize.
Replace the DC controller
Description: The device has experienced a problem with its internal fan.
Remedy: Turn off the power by using the power switch, wait at least 30 seconds, and then turn on the power and wait for the device to initialize. If the error persists, replace the fan. If the error still persists, replace the DC controller.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.