  • Code: 54.16
  • Display: 54.XX ERROR
  • Description: An error has occurred with one of the tonerlevel sensors
    Magenta
  • Remedy: 1. Make sure that connector J1020 on the DC controller is seated correctly. 2. Replace the memory-controller PCA. 3. Replace the DC controller.
  • Code: 54.17
  • Display: 54.XX ERROR
  • Description: An error has occurred with one of the tonerlevel sensors
    Cyan
  • Remedy: 1. Make sure that connector J1020 on the DC controller is seated correctly. 2. Replace the memory-controller PCA. 3. Replace the DC controller.
  • Code: 54.18
  • Display: 54.XX ERROR
  • Description: An error has occurred with one of the tonerlevel sensors
    Black
  • Remedy: 1. Make sure that connector J1020 on the DC controller is seated correctly. 2. Replace the memory-controller PCA. 3. Replace the DC controller.
  • Code: 55.XX.YY
  • Display: 55.XX.YY DC CONTROLLER ERROR
  • Description: A communication error between the DC controller and the formatter has occurred.
  • Remedy: 1. Turn the printer off. 2. Reconnect the connector between the DC controller and the formatter. 3. Replace the DC controller.
  • Code: 57.04
  • Display: 57.XX PRINTER ERROR
  • Description: A printer fan error has occurred.
    Main fan
  • Remedy: 1. Check that connector J1008 on the DC controller is seated correctly. 2. Replace the fan. 3. Replace the DC controller.
  • Code: 57.06
  • Display: 57.XX PRINTER ERROR
  • Description: A printer fan error has occurred.
  • Remedy: 1. Check that connectors J802, J823, and J850 on the duplex-driver PCA are seated correctly. 2. Replace the fan. 3. Replace the duplex-driver PCA.
  • Code: 59.30
  • Display: 59.30 ERROR
  • Description: An error occurred with the fuser motor during startup or rotation.
  • Remedy: 1. Check that connectors J5008 on the fuser motor and J213 on the driver PCA are seated correctly. 2. Replace the fuser. 3. Replace the DC controller.
  • Code: 59.40
  • Display: 59.40 ERROR
  • Description: An error occurred with the fuser motor during startup or rotation.
  • Remedy: 1. Check that connectors J5008 on the fuser motor and J213 on the driver PCA are seated correctly. 2. Replace the fuser. 3. Replace the DC controller.