Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi HP Color LaserJet 3800 — Trang 7/10

Code: 54.16

Display: 54.XX ERROR
Description: An error has occurred with one of the tonerlevel sensors
Magenta
Remedy: 1. Make sure that connector J1020 on the DC controller is seated correctly. 2. Replace the memory-controller PCA. 3. Replace the DC controller.

Code: 54.17

Display: 54.XX ERROR
Description: An error has occurred with one of the tonerlevel sensors
Cyan
Remedy: 1. Make sure that connector J1020 on the DC controller is seated correctly. 2. Replace the memory-controller PCA. 3. Replace the DC controller.

Code: 54.18

Display: 54.XX ERROR
Description: An error has occurred with one of the tonerlevel sensors
Black
Remedy: 1. Make sure that connector J1020 on the DC controller is seated correctly. 2. Replace the memory-controller PCA. 3. Replace the DC controller.

Code: 55.XX.YY

Display: 55.XX.YY DC CONTROLLER ERROR
Description: A communication error between the DC controller and the formatter has occurred.
Remedy: 1. Turn the printer off. 2. Reconnect the connector between the DC controller and the formatter. 3. Replace the DC controller.

Code: 57.04

Display: 57.XX PRINTER ERROR
Description: A printer fan error has occurred.
Main fan
Remedy: 1. Check that connector J1008 on the DC controller is seated correctly. 2. Replace the fan. 3. Replace the DC controller.

Code: 57.06

Display: 57.XX PRINTER ERROR
Description: A printer fan error has occurred.
Remedy: 1. Check that connectors J802, J823, and J850 on the duplex-driver PCA are seated correctly. 2. Replace the fan. 3. Replace the duplex-driver PCA.

Code: 59.30

Display: 59.30 ERROR
Description: An error occurred with the fuser motor during startup or rotation.
Remedy: 1. Check that connectors J5008 on the fuser motor and J213 on the driver PCA are seated correctly. 2. Replace the fuser. 3. Replace the DC controller.

Code: 59.40

Display: 59.40 ERROR
Description: An error occurred with the fuser motor during startup or rotation.
Remedy: 1. Check that connectors J5008 on the fuser motor and J213 on the driver PCA are seated correctly. 2. Replace the fuser. 3. Replace the DC controller.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie