Các lỗi thường gặp

Code :
  • Code: 59.50
  • Display: 59.X Error
  • Description: Image drum motor startup or rotation error-black.
    - Image drum motor startup error-black
  • Remedy: 1. Reconnect the connector (J517) on the ITB motor and the connector (J81) on the DC controller PCA. 2. Run the drum motor drive test in the actuator drive mode to verify that the ITB motor is functioning correctly. If it is not, replace the ITB motor unit.
  • Code: 59.51
  • Display: 59.X Error
  • Description: Image drum motor startup or rotation error-cyan, magenta, or yellow.
    - Image drum motor startup error-cyan
  • Remedy: 1. Reconnect the connector (J515) on the drum motor and the connector (J81) on the DC controller PCA. 2. Run the drum motor drive test in the actuator drive mode to verify that the drum motor is functioning correctly. If it is not, replace the drum motor unit.
  • Code: 59.52
  • Display: 59.X Error
  • Description: Image drum motor startup or rotation error-cyan, magenta, or yellow.
    - Image drum motor startup error-magenta
  • Remedy: 1. Reconnect the connector (J515) on the drum motor and the connector (J81) on the DC controller PCA. 2. Run the drum motor drive test in the actuator drive mode to verify that the drum motor is functioning correctly. If it is not, replace the drum motor unit.
  • Code: 59.53
  • Display: 59.X Error
  • Description: Image drum motor startup or rotation error-cyan, magenta, or yellow.
    - Image drum motor startup error-yellow
  • Remedy: 1. Reconnect the connector (J515) on the drum motor and the connector (J81) on the DC controller PCA. 2. Run the drum motor drive test in the actuator drive mode to verify that the drum motor is functioning correctly. If it is not, replace the drum motor unit.
  • Code: 59.60
  • Display: 59.X Error
  • Description: Image drum motor startup or rotation error-black.
    - Image drum motor rotation error-black
  • Remedy: 1. Reconnect the connector (J517) on the ITB motor and the connector (J81) on the DC controller PCA. 2. Run the drum motor drive test in the actuator drive mode to verify that the ITB motor is functioning correctly. If it is not, replace the ITB motor unit.
  • Code: 59.61
  • Display: 59.X Error
  • Description: Image drum motor startup or rotation error-cyan, magenta, or yellow.
    - Image drum motor rotation error-cyan
  • Remedy: 1. Reconnect the connector (J515) on the drum motor and the connector (J81) on the DC controller PCA. 2. Run the drum motor drive test in the actuator drive mode to verify that the drum motor is functioning correctly. If it is not, replace the drum motor unit.
  • Code: 59.62
  • Display: 59.X Error
  • Description: Image drum motor startup or rotation error-cyan, magenta, or yellow.
    - Image drum motor rotation error-magenta
  • Remedy: 1. Reconnect the connector (J515) on the drum motor and the connector (J81) on the DC controller PCA. 2. Run the drum motor drive test in the actuator drive mode to verify that the drum motor is functioning correctly. If it is not, replace the drum motor unit.
  • Code: 59.63
  • Display: 59.X Error
  • Description: Image drum motor startup or rotation error-cyan, magenta, or yellow.
    - Image drum motor rotation error-yellow
  • Remedy: 1. Reconnect the connector (J515) on the drum motor and the connector (J81) on the DC controller PCA. 2. Run the drum motor drive test in the actuator drive mode to verify that the drum motor is functioning correctly. If it is not, replace the drum motor unit.