Description: (or Front Panel is blank) No comunication between the Front Panel and the Main PCA.
Remedy: • Switch the Power OFF from the back of the Printer and disconnect the Power cord. Reconnect the power cord and power On the Printer. • Check that the Front Panel interface cable is not damaged and is correctly connected between the Main PCA and the Front Panel. • Check that the connections between the Formatter and the Main PCA are not damaged and are correctly connected. • If the System Error continues, replace the Formatter. • If the System Error continues, replace the Main PCA. • If the System Error continues, replace the Front Panel.
Code: 11:YZ
Description: Trailing Cable does not seem to be detected.
Remedy: • Switch the Power OFF from the back of the Printer and disconnect the Power cord. Reconnect the power cord and power On the Printer. • Check that the Trailing Cable is not damaged. • Check that the Trailing Cable is correctly connected betwen the Main PCA and Carriage PCA and make sure that the connectors in these boards are not damaged. • If the System Error continues, replace the Trailing Cable. • If the System Error continues, replace the Main PCA. • If the System Error continues, replace the Carriage PCA.
Code: 21.1:YZ
Description: Fail moving the Primer Motor of the Service Station.
Remedy: • Remove the Right Cover and make sure the cables from the Printmech PCA to the Service Station are connected and are not damaged. • Perform the Service Station diagnostic test to troubleshoot the problem further. • If the System Error continues, replace the Service Station. • If the System Error continues, replace the PrintMech PCA.
Code: 21:YZ
Description: Fail moving Service Station.
Remedy: • Remove the Right Cover and make sure the cables from the Printmech PCA to the Service Station are connected and are not damaged. • Make sure that the Service Station path is clear. Remove any visible obstacles (e.g. screws, plastic parts, etc• .) restricting the movement of the Service Station. • Perform the Service Station diagnostic test to troubleshoot the problem further. • If the System Error continues, replace the Service Station. • If the System Error continues, replace the PrintMech PCA.
Code: 22.0:YZ
Description: Left Ink Supply Station error.
Remedy: • Switch the Power OFF from the back of the Printer and disconnect the Power cord. Reconnect the power cord and power On the Printer. • Check that the cables between the Left Ink Supply Station and Main PCA the are not damaged and are correctly connected. • Perform the Ink Delivery System diagnostic test to troubleshoot the problem further. • If the System Error continues, replace the Left Ink Supply Station. • If the System Error continues, replace the Main PCA.
Code: 22.1:YZ
Description: Left Ink Supply Station error.
Remedy: • Switch the Power OFF from the back of the Printer and disconnect the Power cord. Reconnect the power cord and power On the Printer. • Check that the cables between the Left Ink Supply Station and Main PCA the are not damaged and are correctly connected. • Perform the Ink Delivery System diagnostic test to troubleshoot the problem further. • If the System Error continues, replace the Left Ink Supply Station. • If the System Error continues, replace the Main PCA.
Code: 22.2:YZ
Description: Right Ink Supply Station error.
Remedy: • Switch the Power OFF from the back of the Printer and disconnect the Power cord. Reconnect the power cord and power On the Printer. • Check that the cables between the Right Ink Supply Station and PrintMech PCA the are not damaged and are correctly connected. • Perform the Ink Delivery System diagnostic test to troubleshoot the problem further. • If the System Error continues, replace the Right Ink Supply Station. • If the System Error continues, replace the Main PCA.
Code: 22.3:YZ
Description: Right Ink Supply Station error.
Remedy: • Switch the Power OFF from the back of the Printer and disconnect the Power cord. Reconnect the power cord and power On the Printer. • Check that the cables between the Right Ink Supply Station and PrintMech PCA the are not damaged and are correctly connected. • Perform the Ink Delivery System diagnostic test to troubleshoot the problem further. • If the System Error continues, replace the Right Ink Supply Station. • If the System Error continues, replace the Main PCA.