Description: Scanner Error
The product has experienced an internal hardware error.
Remedy: Turn off the power by using the power switch, wait at least 30 seconds, and then turn on the power and wait for the product to initialize. If a surge protector is being used, remove it. Connect the product directly into the wall socket. Use the power switch to turn the product on.
Code: 54.0100
Description: Environmental sensor error
Remedy: Verify that the DC controller connectors are firmly connected. If the error persists, replace the temperature/humidity sensor. If the error persists, replace the DC controller.
Code: 54.0600
Description: Density sensor error
Remedy: Verify that the cables between the DC controller and the ITB are firmly connected. If the error persists, replace the color misregistration sensor. If the error persists, replace the ITB. If the error persists, replace the DC controller.
Code: 54.1100
Description: Black density out of range
Remedy: Verify that the cables between the DC controller and the ITB are firmly connected. If the error persists, replace the color misregistration sensor. If the error persists, replace the ITB. If the error persists, replace the DC controller.
Code: 54.1101
Description: Cyan density out of range
Remedy: Verify that the cables between the DC controller and the ITB are firmly connected. If the error persists, replace the color misregistration sensor. If the error persists, replace the ITB. If the error persists, replace the DC controller.