Các lỗi thường gặp

Code :
  • Code: 51.XX
  • Display: 51.XX Error
  • Description: The product has experienced an internal hardware error.
  • Remedy: Turn the product power off, wait at least 30 seconds, and then turn the product power on and wait for it to initialize. If you are using a surge protector, remove it. Plug the product directly into the wall socket. Turn the product on.
  • Code: 52.0000
  • Display: 52.0000
  • Description: Engine laser scanner error
  • Remedy:
  • Code: 54.0100
  • Display: 54.0100
  • Description: Environmental sensor error
  • Remedy: Verify that the DC controller connectors are firmly connected. If the error persists, replace the temperature/humidity sensor. If the error persists, replace the DC controller.
  • Code: 54.0600
  • Display: 54.0600
  • Description: Density sensor error
  • Remedy: Verify that the cables between the DC controller is firmly connected. If the error persists, replace the color misregistration sensor. If the error persists, replace the DC controller.
  • Code: 54.1100
  • Display: 54.1100
  • Description: Black density out of range
  • Remedy: Verify that the cables between the DC controller is firmly connected. If the error persists, replace the color misregistration sensor. If the error persists, replace the DC controller.
  • Code: 54.1200
  • Display: 54.1200
  • Description: Black density measurement abnormality
  • Remedy: Verify that the cables between the DC controller is firmly connected. If the error persists, replace the color misregistration sensor. If the error persists, replace the DC controller.
  • Code: 54.1400
  • Display: 54.1400
  • Description: Color plane registration sensor error (inline devices only)
  • Remedy: 1. Turn off the power by using the power switch, and then wait at least 30 seconds. 2. Turn on the power and wait for the product to initialize. If the error persists, verify that the cables between the color misregistration sensor and the DC controller are firmly connected. If the error persists, replace the color misregistration sensor. If the error persists, replace the toner cartridge tray. If the error persists, replace the DC controller.
  • Code: 54.1501
  • Display: 54.1501
  • Description: Cyan CPR pattern cannot be read
  • Remedy: 1. Turn off the power by using the power switch, and then wait at least 30 seconds. 2. Turn on the power and wait for the product to initialize. If the error persists, verify that the cables between the color misregistration sensor and the DC controller are firmly connected. If the error persists, replace the color misregistration sensor. If the error persists, replace the toner cartridge tray. If the error persists, replace the DC controller.