Remedy: 1. Turn the product off, and then on again. 2. If the error persists, turn the product off and then check the scanner wire-harness connectors and the scanner power supply fan. 3. If the error persists, replace the scanner power supply or scanner power supply fan.
Code: 31.01.49
Display: 30.01.YY Scanner Failure
Description: Scanner inverter fan error
Remedy: 1. Turn the product off, and then on again. 2. If the error persists, turn the product off and then check the scanner wire-harness connectors and the scanner power supply fan. 3. If the error persists, replace the scanner power supply, scanner power supply fan, or the SCB.
Code: 31.01.50
Display: 30.01.YY Scanner Failure
Description: Internal SCB error
Remedy: 1. Turn the product off, and then on again. 2. If the error persists, replace the SCB.
Code: 32.08.A1
Display: 32.08.AX
Description: Shutdown event
Remedy: No action necessary.
Code: 32.08.A2
Display: 32.08.AX
Description: Boot from normal shutdown event
Remedy: No action necessary.
Code: 32.08.A3
Display: 32.08.AX
Description: Boot from abnormal shutdown event
Remedy: No action necessary.
Code: 32.1C.01
Display: 32.1C.XX
Description: NVRAM backup/restore service backup started
Remedy: No action necessary
Code: 32.1C.02
Display: 32.1C.XX
Description: NVRAM backup/restore service restore started