Các lỗi thường gặp

Code :
  • Code: 10.22.70
  • Display: Replace Supplies
  • Description: This alert appears only if the product is configured to stop when a supplies reach the very low threshold. Two or more supplies have reached the estimated end of life. The product indicates when a supply level is at its estimated end of life. The actual life remaining might be different than estimated. The supply does not need to be replaced now unless the print quality is no longer acceptable. HP recommends that the customer have a replacement supply available to install when print quality is no longer acceptable. NOTE: When an HP supply has reached its approximated end of life, the HP Premium Protection Warranty on that supply ends. Recorded event codes depend on which supplies are at the end of life.
    Transfer kit
  • Remedy: Press the OK button to find out which supplies need to be replaced. Or, configure the product to continue printing by using the Manage Supplies menu.
  • Code: 10.23.15
  • Display: 10.YY.15 Install <supply>
  • Description: The indicated supply has been removed or installed incorrectly.
    Fuser kit
  • Remedy: Replace or install the indicated supply.
  • Code: 10.23.15
  • Display: Install <supply>
  • Description: A supply item is either not installed or installed incorrectly.
    Fuser kit
  • Remedy: Install the supply item or make sure that the installed supply item is fully seated.
  • Code: 10.23.35
  • Display: Incompatible <supply>
  • Description: The indicated supply <supply>is not compatible with this product.
    Fuser kit
  • Remedy: Replace the supply with one that is designed for this product.
  • Code: 10.23.35
  • Display: 10.YY.35 Incompatible <supply>
  • Description: The indicated supply is not compatible with this product.
    Fuser
  • Remedy: CAUTION: The fuser might be hot. Be careful when removing the fuser. Install a supply that is designed for this product.
  • Code: 10.23.50
  • Display: 10.23.50
  • Description: The fuser kit life was reset above the order threshold. A new ITB was installed.
  • Remedy: No action necessary.
  • Code: 10.23.51
  • Display: 10.23.51
  • Description: The fuser kit life was reset above the replace threshold. A new ITB was installed.
  • Remedy: No action necessary.
  • Code: 10.23.52
  • Display: 10.23.52
  • Description: The fuser kit life was reset above the reset threshold. A new ITB was installed.
  • Remedy: No action necessary.