Code: 54.0X.0C

Display: 54.XX.YY Error
Description: A sensor error has occurred
Density sensor out of range error or Dhalf calibration failure X = 0 black, X = 1 cyan, X = 2 magenta, X = 3 yellow
Remedy: 1. Check the supplies status page to make sure the toner cartridges are not past their useful life. 2. Check the ITB for damage. 3. Make sure the CPR sensor is not contaminated with toner or paper dust. Clean the sensor with compressed air and soft brush. 4. If error persists, replace the registration sensor assembly.

Code: 54.0X.0C

Display: 54.XX.YY Error
Description: A sensor error has occurred
Density sensor out of range error or Dhalf calibration failure X = 0 black, X = 1 cyan, X = 2 magenta, X = 3 yellow
Remedy: 1. Check the supplies status page to make sure the toner cartridges are not past their useful life. 2. Check the ITB for damage. 3. Make sure the CPR sensor is not contaminated with toner or paper dust. Clean the sensor with compressed air and soft brush. 4. If error persists, replace the registration sensor assembly.

Code: 54.0X.0D

Display: 54.XX.YY Error
Description: A sensor error has occurred
Optical memory element abnormal or CPR sensor out of range X = 0 black, X = 1 cyan, X = 2 magenta, X = 3 yellow
Remedy: 1. Check the supplies status page to make sure the toner cartridges are not past their useful life. 2. Check the ITB for damage. 3. Make sure the CPR sensor is not contaminated with toner or paper dust. Clean the sensor with compressed air and soft brush. 4. If error persists, replace the registration sensor assembly.

Code: 54.0X.0D

Display: 54.XX.YY Error
Description: A sensor error has occurred
Optical memory element abnormal or CPR sensor out of range X = 0 black, X = 1 cyan, X = 2 magenta, X = 3 yellow
Remedy: 1. Check the supplies status page to make sure the toner cartridges are not past their useful life. 2. Check the ITB for damage. 3. Make sure the CPR sensor is not contaminated with toner or paper dust. Clean the sensor with compressed air and soft brush. 4. If error persists, replace the registration sensor assembly.

Code: 54.0X.0E

Display: 54.XX.YY Error
Description: A sensor error has occurred
Optical memory element abnormal or CPR sensor out of range X = 0 black, X = 1 cyan, X = 2 magenta, X = 3 yellow
Remedy: 1. Check the supplies status page to make sure the toner cartridges are not past their useful life. 2. Check the ITB for damage. 3. Make sure the CPR sensor is not contaminated with toner or paper dust. Clean the sensor with compressed air and soft brush. 4. If error persists, replace the registration sensor assembly.

Code: 54.0X.0E

Display: 54.XX.YY Error
Description: A sensor error has occurred
Optical memory element abnormal or CPR sensor out of range X = 0 black, X = 1 cyan, X = 2 magenta, X = 3 yellow
Remedy: 1. Check the supplies status page to make sure the toner cartridges are not past their useful life. 2. Check the ITB for damage. 3. Make sure the CPR sensor is not contaminated with toner or paper dust. Clean the sensor with compressed air and soft brush. 4. If error persists, replace the registration sensor assembly.

Code: 55.00.01

Display: 55.00.YY DC controller error To continue, turn off then on
Description: DC controller PCA error
DC controller memory error
Remedy: Turn the product off, and then on. If the error persists, replace the DC controller PCA.

Code: 55.00.02

Display: 55.00.YY DC controller error To continue, turn off then on
Description: DC controller PCA error
DC controller no engine response
Remedy: Turn the product off, and then on. If the error persists, replace the DC controller PCA.