Các lỗi thường gặp

Code :
  • Code: 54.0X.0C
  • Display: 54.XX.YY Error
  • Description: A sensor error has occurred
    Density sensor out of range error or Dhalf calibration failure X = 0 black, X = 1 cyan, X = 2 magenta, X = 3 yellow
  • Remedy: 1. Check the supplies status page to make sure the toner cartridges are not past their useful life. 2. Check the ITB for damage. 3. Make sure the CPR sensor is not contaminated with toner or paper dust. Clean the sensor with compressed air and soft brush. 4. If error persists, replace the registration sensor assembly.
  • Code: 54.0X.0C
  • Display: 54.XX.YY Error
  • Description: A sensor error has occurred
    Density sensor out of range error or Dhalf calibration failure X = 0 black, X = 1 cyan, X = 2 magenta, X = 3 yellow
  • Remedy: 1. Check the supplies status page to make sure the toner cartridges are not past their useful life. 2. Check the ITB for damage. 3. Make sure the CPR sensor is not contaminated with toner or paper dust. Clean the sensor with compressed air and soft brush. 4. If error persists, replace the registration sensor assembly.
  • Code: 54.0X.0D
  • Display: 54.XX.YY Error
  • Description: A sensor error has occurred
    Optical memory element abnormal or CPR sensor out of range X = 0 black, X = 1 cyan, X = 2 magenta, X = 3 yellow
  • Remedy: 1. Check the supplies status page to make sure the toner cartridges are not past their useful life. 2. Check the ITB for damage. 3. Make sure the CPR sensor is not contaminated with toner or paper dust. Clean the sensor with compressed air and soft brush. 4. If error persists, replace the registration sensor assembly.
  • Code: 54.0X.0D
  • Display: 54.XX.YY Error
  • Description: A sensor error has occurred
    Optical memory element abnormal or CPR sensor out of range X = 0 black, X = 1 cyan, X = 2 magenta, X = 3 yellow
  • Remedy: 1. Check the supplies status page to make sure the toner cartridges are not past their useful life. 2. Check the ITB for damage. 3. Make sure the CPR sensor is not contaminated with toner or paper dust. Clean the sensor with compressed air and soft brush. 4. If error persists, replace the registration sensor assembly.
  • Code: 54.0X.0E
  • Display: 54.XX.YY Error
  • Description: A sensor error has occurred
    Optical memory element abnormal or CPR sensor out of range X = 0 black, X = 1 cyan, X = 2 magenta, X = 3 yellow
  • Remedy: 1. Check the supplies status page to make sure the toner cartridges are not past their useful life. 2. Check the ITB for damage. 3. Make sure the CPR sensor is not contaminated with toner or paper dust. Clean the sensor with compressed air and soft brush. 4. If error persists, replace the registration sensor assembly.
  • Code: 54.0X.0E
  • Display: 54.XX.YY Error
  • Description: A sensor error has occurred
    Optical memory element abnormal or CPR sensor out of range X = 0 black, X = 1 cyan, X = 2 magenta, X = 3 yellow
  • Remedy: 1. Check the supplies status page to make sure the toner cartridges are not past their useful life. 2. Check the ITB for damage. 3. Make sure the CPR sensor is not contaminated with toner or paper dust. Clean the sensor with compressed air and soft brush. 4. If error persists, replace the registration sensor assembly.
  • Code: 55.00.01
  • Display: 55.00.YY DC controller error To continue, turn off then on
  • Description: DC controller PCA error
    DC controller memory error
  • Remedy: Turn the product off, and then on. If the error persists, replace the DC controller PCA.
  • Code: 55.00.02
  • Display: 55.00.YY DC controller error To continue, turn off then on
  • Description: DC controller PCA error
    DC controller no engine response
  • Remedy: Turn the product off, and then on. If the error persists, replace the DC controller PCA.