Description: Stopped at registration jam. This jam occurs when the media is longer than the longest Universal size, (470 mm; 18.50 in), by 40 mm (1.57 in) or more, and printing from Tray 1. However, this jam occurs when the media that is longer than the designated length by 40 mm (1.57 in) and more is detected, if the media that is longer than the longest Universal is designated. This jam occurs when the media longer than LEDGER-P by 40 mm (1.57 in) or more is detected at printing from Tray 2. Z = the source tray number
Description: Late to registration jam, from Tray 1 This jam occurs when the paper does not reach the registration (TOP; SR8) sensor in designated amount of time from the start of paper pickup at printing from Tray 1 and duplex printing.
Description: Misfeed jam from Tray 2 This jam occurs when the paper does not reach the registration (TOP; SR8) sensor in designated amount of time from the start of paper pick-up at printing from Tray 2 and duplex printing.
Description: Late to registration jam, from duplexer This jam occurs when the paper does not reach the registration (TOP; SR8) sensor in designated amount of time after it is reversed at the switchback position. Z = D for duplexer
Remedy: Clear the jam.