Description: Manual Feed or Continuable Error
This state occurs in the following circumstances:
- Manual feed
- General continuable error
Remedy: To recover from the error and print the available data, press the Go button.
If the recovery is successful, the device continues to the Processing Data state and completes the job.
If the recovery is unsuccessful, the device continues to the Continuable Error state. Try removing any media from the media path and cycling the device power.
Description: Fatal Error
The device has encountered a nonrecoverable error.
Remedy: Turn off the device, wait 10 seconds, and turn on the device.
- Verify that all connectors to the Engine Controller PCB are securely seated.
- Verify that the motor rotates for approximately six seconds during power up.
- If the motor does not rotate during power up, check all motor drive PCB connections.
- If the motor only rotates for approximately three seconds, check the laser/scanner unit connections.
- If the motor runs for 30 or more seconds during power up, verify all connections in the fusing assembly circuitry are connected correctly.