  • Code: 52.0000
  • Description: Engine laser scanner error
  • Remedy:
  • Code: 54.0100
  • Description: Environmental sensor error
  • Remedy: Verify that the DC controller connectors are firmly connected. If the error persists, replace the temperature/humidity sensor. If the error persists, replace the DC controller.
  • Code: 54.0600
  • Description: Density sensor error
  • Remedy: Verify that the cables between the DC controller is firmly connected. If the error persists, replace the color misregistration sensor. If the error persists, replace the DC controller.
  • Code: 54.1100
  • Description: Black density out of range
  • Remedy: Verify that the cables between the DC controller is firmly connected. If the error persists, replace the color misregistration sensor. If the error persists, replace the DC controller.
  • Code: 54.1200
  • Description: Black density measurement abnormality
  • Remedy: Verify that the cables between the DC controller is firmly connected. If the error persists, replace the color misregistration sensor. If the error persists, replace the DC controller.
  • Code: 54.1400
  • Description: Color plane registration sensor error (inline devices only)
  • Remedy: 1. Turn off the power by using the power switch, and then wait at least 30 seconds. 2. Turn on the power and wait for the product to initialize. If the error persists, verify that the cables between the color misregistration sensor and the DC controller are firmly connected. If the error persists, replace the color misregistration sensor. If the error persists, replace the toner cartridge tray. If the error persists, replace the DC controller.
  • Code: 54.1501
  • Description: Cyan CPR pattern cannot be read
  • Remedy: 1. Turn off the power by using the power switch, and then wait at least 30 seconds. 2. Turn on the power and wait for the product to initialize. If the error persists, verify that the cables between the color misregistration sensor and the DC controller are firmly connected. If the error persists, replace the color misregistration sensor. If the error persists, replace the toner cartridge tray. If the error persists, replace the DC controller.
  • Code: 54.1502
  • Description: Magenta CPR pattern cannot be read
  • Remedy: 1. Turn off the power by using the power switch, and then wait at least 30 seconds. 2. Turn on the power and wait for the product to initialize. If the error persists, verify that the cables between the color misregistration sensor and the DC controller are firmly connected. If the error persists, replace the color misregistration sensor. If the error persists, replace the toner cartridge tray. If the error persists, replace the DC controller.