Code: 94:01

Description: CLC failed because paper white point is out of valid range
Causes: Paper white point is out of valid range.
Remedy: Call agent: • Ensure the loaded substrate is white and there aren't spots on it.

Code: 94:02

Description: CLC failed, inconsistencies in measures detected
Causes: Inconsistencies in CLC measures detected.
Remedy: Call agent: 1. Check substrate type selection in front panel corresponds to actual substrate loaded. 2. Retry calibration.

Code: 94:08

Description: Color Calibration failed
Causes: Color Calibration failed.
Remedy: Call agent: • Try again or check user manual color calibration troubleshooting.

Code: 94:10

Description: CLC measures out of range
Causes: Aerosol or other malfunction of Color Sensor prevents calibration.
Remedy: Service engineer: 1. Retry calibration. 2. Replace SOL.

Code: 98:03

Description: Potential Print Quality problem. Detected too many nozzles out
Causes: Check PH using the PH status plot.
Remedy: Service engineer: • Use the printhead status plot to find out which printheads have a massive number of nozzles out, and replace them.