Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi KIP 7100

Code: E-000

Description: Fuser Temperature Rising Error
Causes: Fuser Temperature does not reach 50C within 120 seconds after turning on.

Code: E-001

Description: Fuser Over Temperature Error
Causes: Fuser Temperature reaches over 230C.

Code: E-002

Description: Fuser Low Temperature Error
Causes: 1. Fuser Temperature at the time of turning on was 50 to 100 oC, but it does not rise up to 120 oC within 150 seconds after that. 2. Fuser Temperature at the time of turning on was higher than 100 oC, but it does not rise up to the setting temperature within 330 seconds after that.

Code: E-003

Description: Fuser Temperature Abnormal Fall Error
Causes: The difference of temperature between center and side of fuser becomes 50C or more.

Code: E-004

Description: Fuser Temperature Abnormal Fall Error
Causes: The Lamp of fuser lights (Signal HEAT1 is “H”) to heat up the Fuser Roller in the ready condition, but even 1 oC of temperature rise can not be accomplished within 30 seconds.

Code: E-010

Description: Main Motor Error
Causes: The Main Motor Output Detection Signal (MAINM_LD) continues to be “H” for 3 seconds or longer when the Main Motor is rotating.

Code: E-011

Description: Fuser Motor Error
Causes: The Fuser Motor Output Detection Signal (HEATM_LD) continues to be “H” for 3 seconds or longer when the Fuser Motor is rotating.

Code: E-012

Description: Developer Press Motor Error
Causes: The Developer Press Sensor Signal (PRESS_S) does not change to “L” within 30 seconds after turning on.