Mã lỗi KIP 9900 — Trang 2/3
Description: Wire Cleaning Error
Causes: Over-current can not be detected although 90 seconds has passed since the Wire Cleaning Motor had started to work.
Description: Fuser Thermostat Error
Causes: Thermostat is open-circuited.
Description: LED Head Cleaning Error
Causes: Over-current can not be detected although 90 seconds has passed since the LED Cleaning Motor had started to work.
Description: Surface Potential Control Error
Causes: When the Auto SP Control fails in adjusting the surface potential to within the acceptable range.
Description: Density Sensor Error
Causes: When the initialization of Density Sensor could not be achieved successfully during Density Lock process.
Description: Density Control Error
Causes: When the Auto Density Control fails in adjusting the density to within the acceptable range.
Description: Developer Disconnection Error
Causes: When the connector in Process Unit is disconnected.
Description: RFID (IC Tag) Error
Causes: When the FRID PCB is defective