Description: Staple Drive Failure
- See FS-530/PU-501/OT-602 service manual.
Remedy:
Code: C11B5
Description: Saddle Staple 1 Drive Failure
- See SD-507 service manual.
Remedy:
Code: C11B6
Description: Saddle Staple 2 Drive Failure
- See SD-507 service manual.
Remedy:
Code: C11C0
Description: Punch Cam Motor Unit Failure
- See FS-530/PU-501/OT-602 service manual.
Remedy:
Code: C11D0
Description: Crease Motor Drive Failure
- See SD-507 service manual.
Remedy:
Code: C2211
Description: IU Motor Failure
- The IU Motor Lock signal remains set to H for a set period of time while the IU Motor is turning.
- The IU Motor Lock signal remains set to L for a set period of time while the IU Motor remains stopped.
Remedy: 1 Check the M2 connector for proper connection and correct as necessary. 2 Check the M2 for proper drive coupling, and correct as necessary. 3 Check the PWB-A connector for proper connection and correct as necessary. 4 M2 operation check PWB-A PJ28A-11 (REM) M-4 5 Change PWB-A. 6 Change PU1.
Code: C2351
Description: Toner Suction Fan Motor Failure
- The Toner Suction Fan Motor Lock signal remains set to H for a set period of time while the Toner Suction Fan Motor is turning.
- The Toner Suction Fan Motor Lock signal remains set to L for a set period of time while the Toner Suction Fan Motor remains stopped.
Remedy: 1 Check the M11 connector for proper connection and correct as necessary. 2 Check the fan for possible overload, and correct as necessary. 3 Check the PWB-A connector for proper connection and correct as necessary. 4 M11 operation check PWB-A PJ5A-13 (REM) D-14 5 Change PWB-A. 6 Change PU1.
Code: C2431
Description: IU Fuse Blowing Failure
- The fuse is not blown even after the lapse of a predetermined period of time.
Remedy: 1 Check the UN2 connector for proper connection and correct as necessary. 2 Remove the Developing Unit from the IU, and then replace UN2. 3 Run F8. 4 Change PWB-A. 5 Change PU1N.