Description: ATDC Sensor Failure
- The scanning value of the ATDC Sensor is less than 7 % while the IU Motor is turning.
- The scanning value of the ATDC Sensor is more than 19 % while the IU Motor is turning.
Remedy: 1 Check the UN2 connector for proper connection and correct as necessary. 2 Remove the Developing Unit from the IU, and then replace UN2. 3 Run F8. 4 Change PWB-A. 5 Change PU1N.
Description: ATDC Adjustment Failure
- The adjustment of the ATDC control voltage could not be completed in the set period of time when function F8 is run.
- The ATDC control voltage was not within the range of 5.39 V to 8.15 V when function F8 is run.
Remedy: 1 Check the UN2 connector for proper connection and correct as necessary. 2 Remove the Developing Unit from the IU, and then replace UN2. 3 Run F8. 4 Change PWB-A. 5 Change PU1N.
Description: EEPROM Failure
- An EEPROM where no initial data is written is detected
Remedy: 1 Disconnect and then connect the power cord. Turn OFF the Main Power Switch, wait for 10 sec. or more, and turn ON the Main Power Switch. 2 Check the EEPROM on the Mechanical Control Board for proper connection, and correct as necessary. 3 Change PWB-A. 4 Change EEPROM.
Description: Fusing Warm-Up Failure (Main)
- The Fusing Roller Thermistor does not detect the required temperature within 30 sec. after a warmup cycle has begun; therefore, the copier does not complete the warm-up cycle.
- The temperature of the Fusing Rollers does not reach the required level even after the set period of time has elapsed during a warm-up cycle.
Remedy: 1 Check that the H1 comes on when the Main Power Switch is set to ON, and correct or replace as necessary. 2 Check that the H2 comes on when the Main Power Switch is set to ON, and correct or replace as necessary. 3 Check the installation of the TH1 and the TH2, and correct or clean as necessary. 4 Check the operation of the TH1. Remove CN80 (4P), and then check that the resistance across CN80-2 and -3 on the Thermistor is infinity. 5 Check the operation of the TH2. Remove CN81 (4P), and then check that the resistance across CN81-2 and -3 on the Thermistor is infinity. 6 Check the continuity of the H1. Correct or replace as necessary. 7 Check the continuity of the H2. Correct or replace as necessary. 8 Change PU1. 9 Change PWB-A.
Description: Fusing Warm-Up Failure (Sub)
- The Fusing Roller Sub Thermistor does not detect the required temperature within 30 sec. after a warm-up cycle has begun; therefore, the copier does not complete the warm-up cycle.
- The temperature of the Fusing Rollers does not reach the required level even after the set period of time has elapsed during a warm-up cycle.
Remedy: 1 Check that the H1 comes on when the Main Power Switch is set to ON, and correct or replace as necessary. 2 Check that the H2 comes on when the Main Power Switch is set to ON, and correct or replace as necessary. 3 Check the installation of the TH1 and the TH2, and correct or clean as necessary. 4 Check the operation of the TH1. Remove CN80 (4P), and then check that the resistance across CN80-2 and -3 on the Thermistor is infinity. 5 Check the operation of the TH2. Remove CN81 (4P), and then check that the resistance across CN81-2 and -3 on the Thermistor is infinity. 6 Check the continuity of the H1. Correct or replace as necessary. 7 Check the continuity of the H2. Correct or replace as necessary. 8 Change PU1. 9 Change PWB-A.
Description: High Fuser Temperature Failure (Main)
- The Fusing Roller Thermistor and Fusing Roller Sub Thermistor are detected to be at a temperature above 240 °C when the Main Power Switch is set to ON.
Remedy: 1 Check that the H1 comes on when the Main Power Switch is set to ON, and correct or replace as necessary. 2 Check that the H2 comes on when the Main Power Switch is set to ON, and correct or replace as necessary. 3 Check the installation of the TH1 and the TH2, and correct or clean as necessary. 4 Check the operation of the TH1. Remove CN80 (4P), and then check that the resistance across CN80-2 and -3 on the Thermistor is infinity. 5 Check the operation of the TH2. Remove CN81 (4P), and then check that the resistance across CN81-2 and -3 on the Thermistor is infinity. 6 Check the continuity of the H1. Correct or replace as necessary. 7 Check the continuity of the H2. Correct or replace as necessary. 8 Change PU1. 9 Change PWB-A.
Description: High Fuser Temperature Failure (Sub)
- The Fusing Roller Thermistor and Fusing Roller Sub Thermistor are detected to be at a temperature above 240 °C when the Main Power Switch is set to ON.
Remedy: 1 Check that the H1 comes on when the Main Power Switch is set to ON, and correct or replace as necessary. 2 Check that the H2 comes on when the Main Power Switch is set to ON, and correct or replace as necessary. 3 Check the installation of the TH1 and the TH2, and correct or clean as necessary. 4 Check the operation of the TH1. Remove CN80 (4P), and then check that the resistance across CN80-2 and -3 on the Thermistor is infinity. 5 Check the operation of the TH2. Remove CN81 (4P), and then check that the resistance across CN81-2 and -3 on the Thermistor is infinity. 6 Check the continuity of the H1. Correct or replace as necessary. 7 Check the continuity of the H2. Correct or replace as necessary. 8 Change PU1. 9 Change PWB-A.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.