Các lỗi thường gặp

Code :
  • Code: C9402
  • Description: Exposure LED lighting abnormally
    The average output value of the CCD sensor with the scanner at its standby position is a predetermined value or more at the end of a scan job.
  • Remedy: 1 Check the connection between SCDB-LU201, and correct if necessary. 2 Check the connector between SCDB PJ1-PRCB CN43 for proper connection and correct as necessary. 3 Check the connector between CCDB PJ3-MFPB PJ01 for proper connection and correct as necessary. 4 Replace the LED exposure unit. 5 Replace CCDB. 6 Replace SCDB. 7 Replace PRCB. 8 Replace MFPB.
  • Code: C9403
  • Description: CIS LED lighting failure
    <When DF-701 is installed> At the CIS gain adjustment, the machine detected that the output of the CIS LED is lower than the specified value.
  • Remedy: 1 Correct the harness connection between CIS and DSIPB if faulty. 2 Correct the harness connection between CIS and CISPU if faulty. 3 Replace CIS. 4 CISPU F1, F2 conduction check. 5 Replace CISPU. 6 Replace DSIPB. 7 Replace MFPB.
  • Code: C9404
  • Description: CIS LED lighting abnormally
    <When DF-701 is installed> After a scan job is completed, the machine detected that the average output of the CIS LED is greater than the specified value.
  • Remedy: 1 Correct the harness connection between CIS and DSIPB if faulty. 2 Correct the harness connection between CIS and CISPU if faulty. 3 Replace CIS. 4 CISPU F1, F2 conduction check. 5 Replace CISPU. 6 Replace DSIPB. 7 Replace MFPB.
  • Code: CA051
  • Description: Standard controller configuration failure
    The controller of the MFP board (MFPB) is faulty.
  • Remedy:
  • Code: CA052
  • Description: Controller hardware error
    A controller hardware error is detected in the network interface.
  • Remedy: 1 Check to see if the following setting has been correctly made: [Service Mode] - [System 2] - [Image Controller Setting]. If changing the setting, turn OFF the main power switch and turn it ON again after 10 seconds or more. 2 Check the connectors of the MFPB for proper connection and correct as necessary. 3 Replace MFPB.
  • Code: CA053
  • Description: Controller start failure
    A controller start failure is detected in the controller interface.
  • Remedy: 1 Check to see if the following setting has been correctly made: [Service Mode] - [System 2] - [Image Controller Setting]. If changing the setting, turn OFF the main power switch and turn it ON again after 10 seconds or more. 2 Check the connectors of the MFPB for proper connection and correct as necessary. 3 Replace MFPB.
  • Code: CB001 ... CB119
  • Description: FAX board error
  • Remedy:
  • Code: CB120 ... CB196
  • Description: Controller error
  • Remedy: