Description: CCD clamp/gain adjustment failure • The adjustment value is 0 or 255 during a CCD clamp adjustment. • The peak value of the output data is 64 or less during a CCD gain adjustment. Scanner
Causes: Exposure unit CCD board (CCDB) MFP board (MFPB)
Remedy: 1 Correct the harness connection between CCDB and MFPB if faulty. 2 Check for possible extraneous light and correct as necessary. 3 Clean the lens, mirrors, CCD surface, and shading sheet if dirty 4 Correct reflective mirror of the scanner if faulty, or change scanner. 5 Change CCDB 6 Change MFPB
Description: ASIC clock input error • When starting the scanner, verification on reading and writing the predetermined value for image processing ASIC on CCD board was conducted, and verification failure was detected.
Causes: MFP board (MFPB) CCD board (CCDB)
Remedy: 1 Correct the harness connection of CCDB if faulty. 2 Change CCDB 3 Change MFPB
Description: Scanner sequence trouble 1 • The original transport interval becomes shorter than the designed value due to an original transport control error in original reading in ADF. Scanner
Causes: MFP board (MFPB) DF control board (DFCB)
Remedy: 1 Correct the harness connection between main body and ADF if faulty. 2 Change DFCB 3 Change MFPB
Description: Before reading pressure welding alienation mechanism • During a pressure motion being performed, the read roller sensor (PS6) output does not change from H to L. • During a retraction motion being performed, the read roller sensor (PS6) output does not change from L to H.
Causes: Reading roller pressure/retraction motor (M4) Read roller sensor (PS6) DF control board (DFCB)
Remedy: 1 Check the motor and sensor connectors for proper connection, and correct as necessary. 2 Check the connector of M4 for proper drive coupling, and correct as necessary. 3 PS6 I/O check, sensor check DFCB PJ6-3 (ON) DF-618 I-4 4 M4 operation check DFCB PJ6-5 to 6 DF-618 I-4 5 Change M4 6 DFCB PS3 conduction check 7 Change DFCB
Description: Turn around pressure welding alienation trouble • During a pressure motion being performed, the reverse roller sensor (PS7) output does not change from H to L. • During a retraction motion being performed, the reverse roller sensor (PS7) output does not change from L to H.
Causes: Switchback roller pressure/retraction motor (M5) Reverse roller sensor (PS7) DF control board (DFCB)
Remedy: 1 Check the motor and sensor connectors for proper connection, and correct as necessary. 2 Check the connector of M5 for proper drive coupling, and correct as necessary. 3 PS7 I/O check, sensor check REYB PJ3-3 (ON) DF-618 K to L-10 4 DFCB F9 conduction check 5 M5 operation check DFCB PJ6-10 to 11 DF-618 I-7 6 Change M5 7 DFCB PS2 conduction check 8 Change DFCB
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.