Description: Ozone fan’s failure to turn. The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Causes: • Ozone fan (FM13) • Printer control board (PRCB)
Remedy: 1 Check the connector between FM13-relay CN165- PRCB CN23 for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM13 operation check PRCB CN23-10 (REM) PRCB CN23-12 (LOCK) 5-C 4 Replace FM13 5 PRCB ICP19 conduction check 6 Replace PRCB
Description: Toner bottle cooling fan’s failure to turn. <bizhub 454e> The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Causes: • Toner bottle cooling fan (FM4) • Printer control board (PRCB)
Remedy: 1 Check the connector between FM4-relay CN111- PRCB CN36 for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM4 operation check PRCB CN36-2 (REM) PRCB CN36-3 (LOCK) 26-C 4 Replace FM4 5 PRCB ICP18 conduction check 6 Replace PRCB
Description: Fusing power supply cooling fan’s failure to turn. <bizhub 454e> The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Causes: • Fusing power supply cooling fan (FM12) • Expansion control board (EXCB) • Printer control board (PRCB)
Remedy: 1 Check the connector between FM12-EXCB CN6 for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM12 operation check EXCB CN6-1 (REM) EXCB CN6-3 (LOCK) 23-T 4 Replace FM12 5 EXCB ICP1 conduction check 6 Replace EXCB 7 Replace PRCB
Description: Machine rear side cooling fan’s failure to turn. The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Remedy: 1 Check the connector between FM3-MFPB PJ26 for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM3 operation check MFPB PJ26-3 (LOCK) 7-P 4 Replace FM3 5 Replace MFPB
Description: MFP control board CPU temperature failure. Temperature failure of CPU on the MFP board was detected.
Causes: • CPU cooling fan (FM14) • MFP board (MFPB)
Remedy: 1 Reboot the machine. 2 Check the connector between FM14-MFPB PJ20 for proper connection and correct as necessary. 3 Check the fan for possible overload and correct as necessary. 4 FM14 operation check MFPB PJ20-1 to 2 1-U to V 5 Replace MFPB
Description: AC signal abnormality. <bizhub 454e> The zero cross signal is not input during fusing phase control.
Causes: • Fusing unit • DC power supply (DCPU) • Printer control board (PRCB)
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the fusing unit, DCPU and PRCB for proper connection and correct or change as necessary 3 Replace fusing unit 4 Replace PRCB 5 Replace DCPU
Description: Expansion control board communication error. Communication error is detected in expansion control board.
Causes: • Expansion control board (EXCB) • Front side board (FRB) • PH unit • Printer control board (PRCB)
Remedy: 1 Reboot the machine. 2 Check the connector between EXCB-PRCB for proper connection and correct as necessary. 3 Check the connector between FRB CN5-PH unit for proper connection and correct as necessary. 4 Check the connector between FRB CN2-PRCB CN8 for proper connection and correct as necessary. 5 Replace EXCB 6 Replace FRB 7 Replace PH unit 8 Replace PRCB
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.