Description: Thermistor /1 (TH1) detects a low temperature when a specified period of time elapses after the fusing heater lamp is turned ON for the fusing ON control.
Causes: Printer control board (PRCB) Fusing heater lamp /1 (L2) Fusing heater lamp /2 (L3) Fusing heater lamp /3 (L4) Thermistor /1 (TH1) Thermistor /2 (TH2) NOTE • C-3401 to C-3901 (fusing temperature related abnormalities) occur, be sure to repair defective parts before setting the software DipSW3-1 to 0. • Setting the DipSW3-1 to 0 with defective parts not repaired may result in a fire.
Description: The temperature of heater does not reach the specified temperature during warming up in alarm recovery.
Causes: Printer control board (PRCB) Fusing heater lamp /1 (L2) Fusing heater lamp /2 (L3) Fusing heater lamp /3 (L4) Thermistor /1 (TH1) Thermistor /2 (TH2) NOTE • C-3401 to C-3901 (fusing temperature related abnormalities) occur, be sure to repair defective parts before setting the software DipSW3-1 to 0. • Setting the DipSW3-1 to 0 with defective parts not repaired may result in a fire.
Description: Thermistor /1 (TH1) does not reach a specified temperature when a specified period of time elapses after the power switch (SW2) is turned ON for the fusing ON control.
Causes: Printer control board (PRCB) Fusing power board (FPB) Fusing heater lamp /1 (L2) Fusing heater lamp /2 (L3) Fusing heater lamp /3 (L4) Thermistor /1 (TH1) Thermistor /2 (TH2) NOTE • C-3401 to C-3901 (fusing temperature related abnormalities) occur, be sure to repair defective parts before setting the software DipSW3-1 to 0. • Setting the DipSW3-1 to 0 with defective parts not repaired may result in a fire.
Description: The WRFAN1_EM signal shows an abnormal condition when a specified period of time elapses after the polygon cooling fan (FM2) turns ON. This abnormal condition recurs when a specified period of time elapses after FM2 is turned OFF and then ON again.
Causes: Polygon cooling fan (FM2) Printer control board (PRCB)
Description: While in the image write, the expansion processing of image data from the memory to the printer is not correctly terminated. The output from the page memory to the printer does not terminate within a specified period of time.
Causes: Printer control board (PRCB) Overall control board (OACB)
Description: One of the following APC errors is detected: • APC is not applicable. • The 12V DC power for the laser drive is not supplied. • MPC is wrong. • Due to the laser defective, the laser does not light up. Or, the index sensor cannot detect the laser due to the followings: • The polygon mirror does not rotate. • The position of the index sensor is not correct. • The index sensor is defective.
Causes: Write unit Power connector of the overall control board (OACB) Printer control board (PRCB)
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.