Description: Laser malfunction • SOS signal is not detected even after the lapse of a given period of time after staring the laser output. • SOS signal is not detected for a given period of time during printing or IDC sensor adjustment.
Causes: PH unit PH relay board (REYB/PH) Printer control board (PRCB)
Remedy: 1 Check the connector for proper connection and correct as necessary. 2 Change PH unit 3 REYB/PH ICP6 conduction check 4 Change REYB/PH 5 PRCB ICP17 conduction check 6 Change PRCB
Description: Transfer belt motor’s failure to turn • The motor lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.
Causes: Transfer belt motor (M1) Printer control board (PRCB)
Remedy: 1 Check the M1 connector for proper connection and correct as necessary. 2 Check M1 for proper drive coupling and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 M1 operation check PRCB CN35-3 (REM) PRCB CN35-6 (LOCK) K-3 5 Change M1 6 PRCB ICP15 conduction check 7 Change PRCB
Description: Transfer belt motor’s turning at abnormal timing • The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Causes: Transfer belt motor (M1) Printer control board (PRCB)
Remedy: 1 Check the M1 connector for proper connection and correct as necessary. 2 Check M1 for proper drive coupling and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 M1 operation check PRCB CN35-3 (REM) PRCB CN35-6 (LOCK) K-3 5 Change M1 6 PRCB ICP15 conduction check 7 Change PRCB
Description: IH cooling fan motor/1’s failure to turn • The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.
Causes: IH cooling fan motor/1 (FM10) Printer control board (PRCB)
Remedy: 1 Check the FM10 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM10 operation check PRCB CN8-5 (REM) PRCB CN8-7 (LOCK) C-16 4 Change FM10 5 PRCB ICP10 conduction check 6 Change PRCB
Description: IH cooling fan motor/2’s failure to turn • The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.
Causes: IH cooling fan motor/2 (FM12) Printer control board (PRCB)
Remedy: 1 Check the FM12 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM12 operation check PRCB CN8-8 (REM) PRCB CN8-10 (LOCK) C-15 4 Change FM12 5 PRCB ICP10 conduction check 6 Change PRCB
Description: Power supply cooling fan motor/1’s failure to turn • The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.
Causes: Power supply cooling fan motor/1 (FM9) DC power supply (DCPU) Printer control board (PRCB)
Remedy: 1 Check the FM9 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM9 operation check DCPU PJ008-3 (LOCK) X-15 4 Change FM9 5 DCPU F551 conduction check 6 Change DCPU 7 Change PRCB
Description: Ozone ventilation fan motor’s failure to turn • The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.
Causes: Ozone ventilation fan motor (FM6) Printer control board (PRCB)
Remedy: 1 Check the FM6 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM6 operation check PRCB CN11-4 (REM) PRCB CN11-6 (LOCK) K-8 4 Change FM6 5 PRCB ICP9 conduction check 6 Change MFPB
Description: Cooling fan motor’s failure to turn • The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.
Causes: Cooling fan motor (FM3) Printer control board (PRCB)
Remedy: 1 Check the FM3 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM3 operation check PRCB CN15-4 (REM) PRCB CN15-6 (LOCK) K-9 4 Change FM3 5 PRCB ICP6 conduction check 6 Change MFPB
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.