Description: Dynamic link error during starting • A dynamic link error occurs in the program on the MFP board due to an insufficient memory space available, a ROM fault, or other reason when the main power switch is turned ON.
Causes: MFP board (MFPB) NVRAM board (NRB)
Remedy: 1 If the malfunction code gC-C172h has occurred, access [Service Mode] - [System 2] - [Image Controller Setting] and check to see if gController 2,h gController 3,h or gOthersh is set for [Image Controller Setting]. If any of these is set, according to the kind of controller, select gController 0h or gController 1.h . . 2 Change MFPB. . . 3 When not reviving even if the above-mentioned procedure is done, contact the responsible people of KMBT.
Description: Dynamic link error during starting (SPF) • A dynamic link error occurs in the program on the MFP board due to an insufficient memory space available, a ROM fault, or other reason when the main power switch is turned ON.
Causes: MFP board (MFPB) NVRAM board (NRB)
Remedy: 1 If the malfunction code gC-C172h has occurred, access [Service Mode] - [System 2] - [Image Controller Setting] and check to see if gController 2,h gController 3,h or gOthersh is set for [Image Controller Setting]. If any of these is set, according to the kind of controller, select gController 0h or gController 1.h . . 2 Change MFPB. . . 3 When not reviving even if the above-mentioned procedure is done, contact the responsible people of KMBT.
Description: Dynamic link error during starting (OAP) • A dynamic link error occurs in the program on the MFP board due to an insufficient memory space available, a ROM fault, or other reason when the main power switch is turned ON.
Causes: MFP board (MFPB) NVRAM board (NRB)
Remedy: 1 If the malfunction code gC-C172h has occurred, access [Service Mode] - [System 2] - [Image Controller Setting] and check to see if gController 2,h gController 3,h or gOthersh is set for [Image Controller Setting]. If any of these is set, according to the kind of controller, select gController 0h or gController 1.h . . 2 Change MFPB. . . 3 When not reviving even if the above-mentioned procedure is done, contact the responsible people of KMBT.
Description: Setting parameter load error (LDR) • Upon startup, the processing of the loadable device driver setting data file failed. - RAM disk file creation failed. - Reading from the flash ROM failed. - An error occurred in API of the authentication module.
Causes: MFP board (MFPB)
Remedy: 1 Turn OFF the main power switch, wait for 10 sec. or more, and turn ON the main power switch. 2 Reinstall the loadable device driver. 3 Rewrite the firmware. 4 Change MFPB.