Description: Glass cleaning mechanism trouble The front side cleaning home sensor (PS18) is not unblocked after the set period of time has elapsed after the front side cleaning motor (M8) is turned ON.
Causes: • Front side cleaning motor (M8) • Front side cleaning home sensor (PS18) • DF control board (DFCB)
Remedy: 1 Check the connector between M8-DFCB CN6 for proper connection and correct as necessary. 2 Check the connector between PS18-DFCB CN3 for proper connection and correct as necessary. 3 Check the connector of M8 for proper drive coupling, and correct as necessary. 4 PS18 I/O check, sensor check DFCB CN3-6 (ON) DF-702 6-C 5 M8 operation check DFCB CN6-1 to 4 DF-702 7-C 6 Replace M8 7 Replace DFCB
Code: C8302
Description: Take-up cooling fan’s failure. While the motor is running, the fan lock signal remains HIGH for a predetermined number of times in a row.
Causes: • Take-up cooling fan (FM1) • DF control board (DFCB)
Remedy: 1 Check the connector of FM1-DFCB CN9 for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM1 operation check DFCB CN9-9 (LOCK) DF-702 4-C 4 Replace FM1 5 DFCB ICP5 conduction check 6 Replace DFCB
Code: C8401
Description: Data flash failure Data flash does not access normally
Causes: DF control board (DFCB)
Remedy: 1 Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2 Check the DFCB connector for proper connection and correct as necessary. 3 Rewrite the firmware. 4 Replace DFCB
Code: C9401
Description: Exposure LED lighting failure • The output from the CCD sensor is a predetermined value or less during CCD sensor gain adjustment. • The wrong model of firmware is detected in the MFP board when the main power switch is turned ON. • The machine type information (Machine, Type) registered to the machine differs from the actual machine type.
Remedy: 1 Check the machine type information registered and reenter as necessary. 2 Check the connection between SCDB and LA201, and correct if necessary. 3 Check the connection between SCDB and MFPB, and correct if necessary. 4 Check that the connection between CCDB and MFPB, and correct if necessary. 5 Replace the LED exposure unit 6 Replace the CCD unit 7 SCDB F1 conduction check 8 Replace SCDB 9 Replace MFPB
Code: C9402
Description: Exposure LED lighting abnormally The average output value of the CCD sensor with the scanner at its standby position is a predetermined value or more at the end of a scan job.
Remedy: 1 Check the machine type information registered and reenter as necessary. 2 Check the connection between SCDB and LA201, and correct if necessary. 3 Check the connection between SCDB and MFPB, and correct if necessary. 4 Check that the connection between CCDB and MFPB, and correct if necessary. 5 Replace the LED exposure unit 6 Replace the CCD unit 7 SCDB F1 conduction check 8 Replace SCDB 9 Replace MFPB
Code: C9403
Description: CIS LED lighting failure At the CIS gain adjustment, the machine detected that the output of the CIS LED is lower than the specified value.
Remedy: 1 Correct the harness connection between CIS and DSIPB if faulty. 2 Correct the harness connection between CIS and DFPU if faulty. 3 Replace CIS 4 Replace DFPU 5 Replace DSIPB 6 Replace MFPB
Code: C9404
Description: CIS LED lighting abnormally After a scan job is completed, the machine detected that the average output of the CIS LED is greater than the specified value.
Remedy: 1 Correct the harness connection between CIS and DSIPB if faulty. 2 Correct the harness connection between CIS and DFPU if faulty. 3 Replace CIS 4 Replace DFPU 5 Replace DSIPB 6 Replace MFPB
Code: CA051
Description: Standard controller configuration failure The controller of the MFP board (MFPB) is faulty.
Causes: MFP board (MFPB)
Remedy: 1 Check to see if [Service Mode] -> [System 2] -> [Image Controller Setting] has been set to “Controller 0.” If changing the setting, turn OFF the main power switch and turn it ON again after 10 seconds or more. 2 Check the connectors of MFPB for proper connection and correct as necessary. 3 Replace MFPB