Remedy: 1 Correct the harness connection of DSCB/2 if faulty. 2 Correct the harness connection of DSIPB if faulty. 3 Replace DSCB/2 4 Replace DSIPB 5 Replace MFPB
Remedy: 1 Correct the harness connection of DSCB/2 if faulty. 2 Correct the harness connection of DSIPB if faulty. 3 Replace DSCB/2 4 Replace DSIPB 5 Replace MFPB
Description: Scanner sequence trouble 1 The original transport interval becomes shorter than the predetermined value due to an original transport control error in original reading in DF.
Causes: • MFP board (MFPB) • DF control board (DFCB)
Remedy: 1 Correct the harness connection between main body and DF if faulty. 2 Replace DFCB 3 Replace MFPB
Description: Before reading pressure/retraction alienation mechanism • During a pressure motion being performed, the before read sensor (PS6) output does not change from H to L. • During a retraction motion being performed, the before read sensor (PS6) output does not change from L to H.
Causes: • Reading roller pressure/retraction motor (M6) • Before read sensor (PS6) • DF control board (DFCB)
Remedy: 1 Check the connector between M6-DFCB CN4 for proper connection, and correct as necessary. 2 Check the connector of M6 for proper drive coupling, and correct as necessary. 3 Check the connector between PS6-DFCB CN9 for proper connection, and correct as necessary. 4 PS6 I/O check, sensor check DFCB CN9-5 (ON) DF-702 3-C 5 M6 operation check DFCB CN4-20 (ON) DF-702 10-C 6 Replace M6 7 DFCB ICP9 conduction check 8 Replace DFCB
Description: Lift up mechanism trouble (Upward movement) The lift up upper sensor (PS2) is not unblocked after a lapse of a given time after the lift-up motor (M5) moves up (is turned forward).
Causes: • Lift-up motor (M5) • Lift-up upper sensor (PS2) • DF control board (DFCB)
Remedy: 1 Check the connector between M5-DFCB CN11 for proper connection, and correct as necessary. 2 Check the connector of M5 for proper drive coupling, and correct as necessary. 3 Check the connectors between PS2-relay CN110- DFCB CN5 for proper connection, and correct as necessary. 4 PS2 I/O check, sensor check DFCB CN5-3 (ON) DF-702 10-C 5 M5 operation check DFCB CN11-4 to 7 DF-702 13-C 6 Replace M5 7 DFCB ICP13 conduction check 8 Replace DFCB
Description: Lift up mechanism failure (Downward movement) The lift up lower sensor (PS3) is not blocked after a lapse of a given time after the lift-up motor (M5) goes down (is turned backward).
Causes: • Lift-up motor (M5) • Lift-up lower sensor (PS3) • DF control board (DFCB)
Remedy: 1 Check the connector between M5-DFCB CN11 for proper connection, and correct as necessary. 2 Check the connector of M5 for proper drive coupling, and correct as necessary. 3 Check the connector between PS3-DFCB CN12 for proper connection, and correct as necessary. 4 PS3 I/O check, sensor check DFCB CN12-12 (ON) DF-702 12-C 5 M5 operation check DFCB CN11-4 to 7 DF-702 13-C 6 Replace M5 7 DFCB ICP13 conduction check 8 Replace DFCB
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin