Description: Faulty ATDC Sensor
- The measurement taken by the ATDC Sensor (UN1) at a time 2.0 sec. after the Main Motor (M1) has started turning is less than 5% (greater than 4.63 V).
- The measurement taken by the ATDC Sensor (UN1) at a time 2.0 sec. after the Main Motor (M1) has started turning is 19% or more (1.41 V or less).
Remedy: 1 Check to see if developer is available. 2 Check the ATDC Sensor connectors for proper connection and correct as necessary. 3 Change UN1. 4 Run ?gATDC Auto Adjust. 5 Change PWB-A. 6 Change PU1.
Description: Improperly adjusted ATDC Sensor
- The adjustment of the ATDC control voltage is not completed within 1 sec. after sampling has started of the ATDC Sensor (UN1) as part of an operation of ATDC Sensor Automatic Adjustment.
- The ATDC Sensor control voltage falls outside the range of 5.39 V to 8.15 V during an operation of ATDC Sensor Automatic Adjustment.
Description: Engine connection failure
Master Board (PWB-A) to Control Board (PWB-C/C) connection failure
- There is no acknowledge signal transmitted from the Master Board (PWB-A) to Control Board (PWB-C/C) for 1.5 sec. or more.
- An error command signal is transmitted from the Control Board (PWB-C/C) to Master Board (PWB-A).
- An error status signal is transmitted from the Master Board (PWB-A) to Control Board (PWB-C/C).
Remedy: 1 Turn OFF and ON the Power Switch. 2 Check the PWB-A connectors for proper connection and correct as necessary. 3 Check the PWB-C/C connectors for proper connection and correct as necessary. 4 Check for proper connection between PWB-A and PWB-C/C and correct as necessary. 5 Change PWB-A. 6 Change PWB-C/C.
Description: Polygon Motor malfunction
-Startup failure
- Lock signal fault: Unstable after the first Lock signal has been detected
- Lock signal fault: Lock signal out-of-timing
Remedy: 1 Turn OFF and ON the Power Switch. 2 Check for proper connection between the PH Unit and Master Board and correct as necessary. 3 Change the PH Unit. 4 Change PWB-A.
Description: Communication with option error
- It is not possible to communicate with the Printer Board within a predetermined period of time during a print cycle.
Description: Faulty HSYNC
Laser scanning system malfunction
- The SOS Sensor does not detect a rising edge of SOS within a given period of time after the Polygon Motor (M2) has started turning and a laser output has been started.
- The SOS Sensor detects no rising edges of SOS while VIA (image area control) is ON.
Remedy: 1 Turn OFF and ON the Power Switch. 2 Check for proper connection between the PH Unit and Master Board and correct as necessary. 3 Change the PH Unit. 4 Change PWB-A.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.