Các lỗi thường gặp

Code :
  • Code: CD201 ... CD203
  • Description: File memory mounting error. Memory capacity discrepancy. Memory capacity discrepancy 2
  • Causes: • MFP board (MFPB) • MEMB/1 (MEMB/1) • MEMB/2 (MEMB/2; UK-204)
  • Remedy: 1 Check to see if MEMB/1 or MEMB/2 is installed correctly. 2 Replace MEMB/1 or MEMB/2 3 Replace MFPB
  • Code: CD211
  • Description: PCI-SDRAM DMA operation failure Hardware related to the transfer of memory image of the printer control board (PRCB) fails to respond.
  • Causes: MFP board (MFPB)
  • Remedy: 1 Replace MFPB
  • Code: CD212
  • Description: Compression/extraction timeout detection Hardware related to the BTC compression function of the printer control board (PRCB) fails to respond.
  • Causes: MFP board (MFPB)
  • Remedy: 1 Replace MFPB
  • Code: CD241, CD242
  • Description: Encryption ASIC error. Encryption ASIC mounting error
  • Causes: MFP board (MFPB)
  • Remedy: 1 Check the MFP board connector for proper connection and correct as necessary. 2 Replace MFPB
  • Code: CD261
  • Description: USB host board failure • When a failure is detected in USB host board included in the local interface kit. • Non-standard USB device is connected.
  • Causes: • MFP board (MFPB) • USB host board (EK-604)
  • Remedy: 1 Check the operation with another USB device. 2 Check the USB host board connector for proper connection and correct as necessary. 3 Replace the USB host board. 4 Replace MFPB.
  • Code: CD271
  • Description: i-Option activated and additional memory not installed While the i-Option is activated, the additional memory included in UK-204 is not installed.
  • Causes: • MFP board (MFPB) • Memory board/2 (MEMB/2; UK-204)
  • Remedy: 1 Check MEMB/2 for proper connection and correct as necessary. 2 Replace MEMB/2 3 Replace MFPB
  • Code: CD272
  • Description: i-Option activated and additional memory and HDD not installed While the i-Option is activated, the additional memory included in UK-204 and the hard disk are not installed.
  • Causes: • MFP board (MFPB) • Hard disk • Memory board/2 (MEMB/2; UK-204)
  • Remedy: 1 Check MEMB/2 for proper connection and correct as necessary. 2 Access [Service Mode] -> [System 2] -> [HDD] and check to see if “Installed” is selected. 3 Replace MEMB/2 4 Replace the hard disk 5 Replace MFPB
  • Code: CD291
  • Description: CCD parameter mismatch The CCD unit is combined with wrong firmware.
  • Causes: • CCD unit • MFP firmware
  • Remedy: 1 Reinstall the MFP firmware.