Description: Abnormality of the 12V power for the PF drive board (PFUDB) of the 2nd tandem PF-703/706. An error detection signal of the PFUDB (blowout of 12V ICP) is detected.
Causes: PF drive board (PFUDB: PF-703/706)
Remedy: 1. Check the connector connection and the wiring on PFUDB, and repair it if any abnormality. 2. Replace PFUDB.
Code: C-0422
Description: Abnormality of the 24V power for the PF drive board (PFUDB) of the 1st tandem PF-703/706. While in printing, an error detection signal (24V power DOWN) of the PFUDB is detected.
Causes: PF drive board (PFUDB: PF-703/706)
Remedy: 1. Check the connector connection and the wiring on PFUDB, and repair it if any abnormality. 2. Replace PFUDB.
Code: C-0423
Description: Abnormality of the 24V power for the PF drive board (PFUDB) of the 2nd tandem PF-703/706. While in printing, an error detection signal (24V power DOWN) of the PFUDB is detected.
Causes: PF drive board (PFUDB: PF-703/706)
Remedy: 1. Check the connector connection and the wiring on PFUDB, and repair it if any abnormality. 2. Replace PFUDB.
Code: C-0424
Description: Abnormality of the 12V power for the PF drive board (PFUDB) of PI-PFU (PF-703). An error detection signal of the PFUDB (blowout of 12V ICP) is detected.
Causes: PF drive board (PFUDB: PF-703)
Remedy: 1. Check the connector connection and the wiring on PFUDB, and repair it if any abnormality. 2. Replace PFUDB.
Code: C-0425
Description: Abnormality of the 24V power for the PF drive board (PFUDB) of PI-PFU (PF-703). While in printing, an error detection signal (24V power DOWN) of the PFUDB is detected.
Causes: Abnormality of the 24V power for the PF drive board (PFUDB) of PI-PFU (PF-703). While in printing, an error detection signal (24V power DOWN) of the PFUDB is detected.
Remedy: 1. Check the connector connection and the wiring on PFUDB, and repair it if any abnormality. 2. Replace PFUDB.
Code: C-0501
Description: 1st tandem PF-703 paper leading edge separation fan /Fr1 (FM3) power abnormality. The FM3EM error detection signal is detected twice in succession within a specified period of time after FM3 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Causes: • Paper leading edge separation fan /Fr1 (FM3: PF-703) • PF drive board (PFUDB: PF-703)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 6-F) 3. Replace FM3 and PFUDB.
Code: C-0502
Description: 1st tandem PF-703 paper leading edge separation fan /Fr1 (FM3) rotation abnormality. The FM3EM error detection signal is detected twice in succession within a specified period of time after FM3 was turned ON. However, an error detection signal (blowout of ICP) is not detected.
Causes: • Paper leading edge separation fan /Fr1 (FM3: PF-703) • PF drive board (PFUDB: PF-703)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 6-F) 3. Replace FM3. 4. Replace PFUDB.
Code: C-0503
Description: 1st tandem PF-703 paper leading edge separation fan /Fr2 (FM7) power abnormality. The FM7EM error detection signal is detected twice in succession within a specified period of time after FM7 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Causes: • Paper leading edge separation fan /Fr2 (FM7: PF-703) • PF drive board (PFUDB: PF-703)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 11-F) 3. Replace FM7 and PFUDB.