Code: C-0680

Description: PI-PFU (PF-703) dehumidification heater /1 (HTR1) temperature rise abnormality. The temperature sensor /5 (TEMS/5) detects the heater temperature lower than 40°C a specified period of time after the heater is turned ON.
Causes: • Upper tray fan heater (HT-505) • AC drive board /2 (ACDB/2: HT-505) • PF drive board (PFUDB: PF-703)
Remedy: 1. Check the connection between ACDB/2 and the noise filter of PF-703. 2. Check the connector connection and the wiring between ACDB /2 and the fan heater, and repair it if any abnormality. 3. Check the connector connection and the wiring between PFUDB and the fan heater, and repair it if any abnormality. 4. Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. 5. Check the temperature and the installation of the fan heater, and repair it if any abnormality. 6. Replace the fan heater. 7. Replace ACDB/2. 8. Replace PFUDB.

Code: C-0681

Description: PI-PFU (PF-703) dehumidification heater /2 (HTR2) temperature rise abnormality. The temperature sensor /6 (TEMS/6) detects the heater temperature lower than 40°C a specified period of time after the heater is turned ON.
Causes: • Middle tray fan heater (HT-505) • AC drive board /2 (ACDB/2: HT-505) • PF drive board (PFUDB: PF-703)
Remedy: 1. Check the connection between ACDB/2 and the noise filter of PF-703. 2. Check the connector connection and the wiring between ACDB /2 and the fan heater, and repair it if any abnormality. 3. Check the connector connection and the wiring between PFUDB and the fan heater, and repair it if any abnormality. 4. Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. 5. Check the temperature and the installation of the fan heater, and repair it if any abnormality. 6. Replace the fan heater. 7. Replace ACDB/2. 8. Replace PFUDB.

Code: C-0682

Description: PI-PFU (PF-703) dehumidification heater /3 (HTR3) temperature rise abnormality. The temperature sensor /7 (TEMS/7) detects the heater temperature lower than 40°C a specified period of time after the heater is turned ON.
Causes: • Lower tray fan heater (HT-505) • AC drive board /2 (ACDB/2: HT-505) • PF drive board (PFUDB: PF-703)
Remedy: 1. Check the connection between ACDB/2 and the noise filter of PF-703. 2. Check the connector connection and the wiring between ACDB /2 and the fan heater, and repair it if any abnormality. 3. Check the connector connection and the wiring between PFUDB and the fan heater, and repair it if any abnormality. 4. Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. 5. Check the temperature and the installation of the fan heater, and repair it if any abnormality. 6. Replace the fan heater. 7. Replace ACDB/2. 8. Replace PFUDB.

Code: C-1001

Description: Serial communication error between the main body and the finishing option.
Causes: Finishing: Communication error
Remedy: 1. Turn OFF the sub power switch, and then turn OFF the main power switch. Then unplug all the power plug. Restart the main body after 10 seconds. 2. Check the connector connection and the wiring between the main body and each option, and repair it if any abnormality. 3. Check the connector connection of the control board and the drive board in each option, and repair it if any abnormality. 4. Rewrite the firmware of the option. 5. Replace the control board of the option corresponds to the malfunction code.

Code: C-1005

Description: Communication error.
Causes: • Printer control board (PRCB) • FNS control board (FNSCB)
Remedy: 1. Turn OFF the sub power switch, and then turn OFF the main power switch. Then unplug all the power plug. Restart the main body after 10 seconds. 2. Check the connector connection and the wiring between the main body and each option, and repair it if any abnormality. 3. Check the connector connection of the control board and the drive board in each option, and repair it if any abnormality. 4. Rewrite the firmware of the option. 5. Replace the control board of the option corresponds to the malfunction code.

Code: C-1006

Description: Communication error.
Causes: • Printer control board (PRCB) • FD control board (FDCB)
Remedy: 1. Turn OFF the sub power switch, and then turn OFF the main power switch. Then unplug all the power plug. Restart the main body after 10 seconds. 2. Check the connector connection and the wiring between the main body and each option, and repair it if any abnormality. 3. Check the connector connection of the control board and the drive board in each option, and repair it if any abnormality. 4. Rewrite the firmware of the option. 5. Replace the control board of the option corresponds to the malfunction code.

Code: C-1007

Description: Communication error.
Causes: • Printer control board (PRCB) • SD control board (SDCB)
Remedy: 1. Turn OFF the sub power switch, and then turn OFF the main power switch. Then unplug all the power plug. Restart the main body after 10 seconds. 2. Check the connector connection and the wiring between the main body and each option, and repair it if any abnormality. 3. Check the connector connection of the control board and the drive board in each option, and repair it if any abnormality. 4. Rewrite the firmware of the option. 5. Replace the control board of the option corresponds to the malfunction code.

Code: C-1009

Description: Communication error between Main CPU in the PB control board (PBCB) and Sub CPU1.
Causes: • PB control board (PBCB) • Control program
Remedy: 1. Turn OFF the sub power switch and then turn OFF the main power switch. Then unplug all the power plug. Restart the main body after 10 seconds. 2. Check the connector connection of the control board and the drive board in PB, and repair it if any abnormality. 3. Rewrite the firmware of PB. 4. Replace PBCB.