Description: Blade motor (M22) abnormality. Waste blade motor does not move to the weak pressure position within a specified period of time after M22 turns ON.
Causes: • Blade sensor /1 (PS24) • Blade sensor /2 (PS25) • Blade motor (M22) • Printer control board (PRCB)
Remedy: 1. Check the connector connection and the wiring between PRCB and motor/sensor, and repair it if any abnormality. 2. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram:Main body (3/4): 14-I) 3. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: Main body (3/4): 14-I, 15-I) 4. Replace PS24 or PS25. 5. Replace M22. 6. Replace PRCB.
Description: Abnormality of the intermediate hopper motor (M11) drive in the printer control board (PRCB).
Causes: • Intermediate hopper motor (M11) • Printer control board (PRCB)
Remedy: 1. Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality 2. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram:Main body (3/4): 2-P) 3. Replace M11 and PRCB at a time.
Description: Drum cleaner motor (M35) abnormality The M35 EM error detection signal is detected twice in succession within a specified period of time after M35 was turned ON.
Causes: • Drum cleaner motor (M35) • Printer control board (PRCB)
Remedy: 1. Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. 2. Rotate the motor by I/O or hand, and repair/replace it if any abnormality. (Wiring diagram: Main body (3/4): 15-P) 3. Replace M35. 4. Replace PRCB.
Description: Developing suction fan (FM22) rotation abnormality + 24V power abnormality. The FM5 EM error detection signal is detected twice in succession within a specified period of time after FM22 was turned ON. At this time, an error detection signal (24V cut off) is detected.
Causes: • DC power supply /2 (DCPS/2) • Printer control board (PRCB)
Remedy: 1. Check the connector connection and the wiring between PRCB and DCPS /2, and repair it if any abnormality. 2. Replace DCPS /2 3. Replace PRCB.
Description: Developing suction fan (FM22) rotation abnormality. The FM5 EM error detection signal is detected twice in succession within a specified period of time after FM22 was turned ON. However, error detection signal (24V cut off) is not detected.
Causes: • Developing suction fan (FM22) • Printer control board (PRCB)
Remedy: 1. Check the connector connection and the wiring between PRCB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: Main body (2/4): 13-A) 3. Replace FM22. 4. Replace PRCB.
Description: Developing cooling fan /Up (FM31) rotation abnormality + 24V power abnormality. The FM31EM error detection signal is detected twice in succession within a specified period of time after FM31 was turned ON. At this time, an error detection signal (24V cut off) is detected.
Causes: • DC power supply /2 (DCPS/2) • Printer control board (PRCB)
Remedy: 1. Check the connector connection and the wiring between PRCB and DCPS /2, and repair it if any abnormality. 2. Replace DCPS /2 3. Replace PRCB.
Description: Developing cooling fan (FM31) rotation abnormality. The FMx EM error detection signal is detected twice in succession within a specified period of time after FMx was turned ON. However, error detection signal (24V cut off) is not detected.
Causes: • Developing cooling fan (FM31) • Printer control board (PRCB)
Remedy: 1. Check the connector connection and the wiring between PRCB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: Main body (2/4): 11-A) 3. Replace FM31. 4. Replace PRCB.
Description: Developing cooling fan (FM11) rotation abnormality + 24V power abnormality. The FM11EM error detection signal is detected twice in succession within a specified period of time after FM11 was turned ON. At this time, an error detection signal (24V cut off) is detected.
Causes: • DC power supply /2 (DCPS/2) • AC drive board (ACDB)
Remedy: 1. Check the connector connection and the wiring between ACDB and DCPS /2, and repair it if any abnormality. 2. Replace DCPS /2 3. Replace ACDB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.