Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Konica-Minolta bizhub C10 — Trang 3/4

Code: 1AH

Description: Abnormally high heating roller temperature
• The temperature detected by the thermistor is a predetermined value or higher for a predetermined period of time.
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the fusing unit, DCPU1, and PRCB for proper connection and correct as necessary. 3 Check the lever of the safety switch and correct as necessary. 4 Change the fusing unit. 5 Change PRCB. 6 Change DCPU1.

Code: 1BH

Description: Faulty thermistor
• The condition of a temperature rise of less than 1°C extends continuously for a predetermined period of time that begins when the warm-up cycle is started.
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the fusing unit, DCPU1, and PRCB for proper connection and correct as necessary. 3 Check the lever of the safety switch and correct as necessary. 4 Change the fusing unit. 5 Change PRCB. 6 Change DCPU1.

Code: 21H

Description: Faulty OHP sensor
• It is determined that the OHP sensor is faulty through a check made at the end of the predrive.
Remedy: 1 Check the PRCB connector for proper connection and correct as necessary. 2 PS2 sensor check. 3 Change PRCB.

Code: 23H

Description: Faulty waste toner near full detection board
• It is determined that the LED and photo receiver are faulty through a check made when a new drum cartridge is detected.
Remedy: 1 Check the WTDTB/LED connector for proper connection and correct as necessary. 2 Check the PRCB connector for proper connection and correct as necessary. 3 Change the drum cartridge. 4 Change WTDTB/LED. 5 Change PRCB.

Code: 24H

Description: Faulty fusing thermistor resistor
• The heater lamp remains ON for a predetermined consecutive period of time.
Remedy:

Code: 29H, 2AH. 2BH, 2CH

Description: Trouble related to security
• Contact the responsible people of KONICA MINOLTA when not returning in power switch OFF/ON.
Remedy:

Code: 2DH

Description: Trouble related to security
• Re-write the controller firmware.
• Contact the responsible people of KONICA MINOLTA when not returning in power switch OFF/ON.
Remedy:

Code: 31H

Description: IR cooling fan motor malfunction
• The fan motor lock signal remains HIGH for a predetermined consecutive period of time while the cooling fan motor remains energized.
Remedy: 1 Check the FM3 connector for proper connection and correct as necessary. 2 Check FM3 for proper drive coupling and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 FM3 operation check. 5 Change PRCB. 6 Change DCPU2. 7 Change DCPU1.