Description: FS NVRAM memory error
<When FS-529 is installed> • When the main power switch is turned ON, malfunctioning of the non-volatile memory on the FS control board (FSCB) is detected.
Remedy: 1 Disconnect and then connect the power cord. Turn OFF the main power switch, wait for 10 sec. or more, and turn ON the main power switch. 2 Rewrite the firmware. 3 Change FSCB.
Description: Transfer belt pressure welding alienation
• The transfer belt retraction sensor does not detect “switch from retraction to pressure” within a given period time after transfer belt retraction clutch has stared engagement. • The transfer belt retraction sensor does not detect “switch from pressure to retraction” within a given period time after transfer belt retraction clutch has stared engagement.
Remedy: 1 Check the connector between M1-PRCB CN14 for proper connection and correct as necessary. 2 Check the connector of M1 for proper drive coupling and correct as necessary. 3 Check the connector between PS39-relay CN124-PRCB CN3 for proper connection and correct as necessary. 4 Check the connector between CL5-relay CN103-PRCB CN24 for proper connection and correct as necessary. 5 PS39 I/O check, sensor check PRCB CN3-15 (ON) 6 CL5 operation check PRCB CN24-4 (ON) 7 M1 operation check PRCB CN14-2 (REM) PRCB CN14-5 (LOCK) C-2 to 5 8 Change M1. 9 PRCB ICP5 conduction check. 10 Change PRCB.
Description: PC charge malfunction
• When electrostatic charge output is ON, electrostatic charge leak detection system continues to detect leaks for a predetermined period of time.
Remedy: 1 Check the drum unit for proper connection and correct as necessary. 2 Check the HV CN1HV, CN2HV connector for proper connection and correct as necessary. 3 Check the PRCB CN17, CN20 connector for proper connection and correct as necessary. 4 Change drum unit. 5 Change HV. 6 Change PRCB.
Description: Color PC motor’s failure to turn
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
Remedy: 1 Check the connector between M2-PRCB CN14 for proper connection and correct as necessary. 2 Check the M2 connector for proper drive coupling and correct as necessary. 3 M2 operation check PRCB CN14-8 (REM) PRCB CN14-10 (LOCK) C-2 to 5 4 Change M2. 5 Change PRCB.
Description: Color PC motor’s turning at abnormal timing
• The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Remedy: 1 Check the connector between M2-PRCB CN14 for proper connection and correct as necessary. 2 Check the M2 connector for proper drive coupling and correct as necessary. 3 M2 operation check PRCB CN14-8 (REM) PRCB CN14-10 (LOCK) C-2 to 5 4 Change M2. 5 Change PRCB.
Description: Color developing unit de-engagement failure
• Engagement is not completed in a given period time after the color dev. unit engaged motor has started engagement operation. • De-engagement is not completed in a given period time after the color dev. unit engaged motor has started de-engagement operation.
Remedy: 1 Check the connector between M10-PRCB CN8 for proper connection and correct as necessary. 2 Check the M10 connector for proper drive coupling and correct as necessary. 3 Check the connector between PS37-PRCB CN8 for proper connection and correct as necessary. 4 Check the connector between CL6-relay CN102-PRCB CN24 for proper connection and correct as necessary. 5 PS37 I/O check, sensor check PRCB CN8-15 (ON). 6 CL6 operation check PRCB CN24-2 (ON). 7 M10 operation check PRCB CN8-16 to 17. 8 Change M10. 9 PRCB ICP5, 7 conduction check. 10 Change PRCB.
Description: Transfer belt cleaner cooling fan motor’s failure to turn
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
Remedy: 1 Check the connector between FM6-relay CN127-relay CN126-PRCB CN3 for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM6 operation check PRCB CN3-17 (REM) PRCB CN3-18 (LOCK). 4 Change FM6. 5 PRCB ICP2 conduction check. 6 Change PRCB.
Description: Developing unit (C) new article release
• The status with the new unit is not cleared after the new developing unit is set.
Remedy: 1 Reinstall developing unit. 2 Check the connector between developing unit-FREYB CN4, CN6, CN8, CN10 for proper connection and correct as necessary. 3 Check the connector between FREYB CN1, CN2-PRCB CN4, CN5 for proper connection and correct as necessary. 4 Change toner developing unit. 6 Change FREYB. 6 PRCB ICP12 conduction check. 7 Change PRCB
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.