Description: PC motor’s turning at abnormal timing
The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Remedy: 1 Check the connector between M2-PRCB CN31 for proper connection and correct as necessary. 2 Check the M2 connector for proper drive coupling and correct as necessary. 3 M2 operation check PRCB CN31-9 (REM) PRCB CN31-12 (LOCK) 4 Replace M2. 5 Replace PRCB.
Description: Developing motor’s failure to turn
The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
Remedy: 1 Check the connector between M21-PRCB CN32 for proper connection and correct as necessary. 2 Check the M21 connector for proper drive coupling and correct as necessary. 3 M21 operation check PRCB CN32-2 (REM) PRCB CN32-5 (LOCK). bizhub C224 25-I to J 4 Replace M21. 5 Replace PRCB.
Description: Developing motor’s turning at abnormal timing
The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Remedy: 1 Check the connector between M21-PRCB CN32 for proper connection and correct as necessary. 2 Check the M21 connector for proper drive coupling and correct as necessary. 3 M21 operation check PRCB CN32-2 (REM) PRCB CN32-5 (LOCK). bizhub C224 25-I to J 4 Replace M21. 5 Replace PRCB.
Description: Transfer belt cleaner cooling fan motor’s failure to turn
The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Remedy: 1 Check the connector between FM2-relay CN115- PRCB CN13 for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM2 operation check PRCB CN13-8 (REM) PRCB CN13-10 (LOCK) 24-C. 4 Replace FM2. 5 PRCB ICP3 conduction check. 6 Replace PRCB.
Description: Developing unit/C new article release
The status with the new unit is not cleared after the new developing unit is set.
Remedy: 1 Reinstall developing unit. 2 Check the connector between developing unit-FRB CN13, CN14, CN15, CN16 for proper connection and correct as necessary. 3 Check the connector between FRB CN1, CN3-PRCB CN7, CN9 for proper connection and correct as necessary. 4 Replace the developing unit. 5 Replace FRB. 6 Replace PRCB.
Description: Developing unit/M new article release
The status with the new unit is not cleared after the new developing unit is set.
Remedy: 1 Reinstall developing unit. 2 Check the connector between developing unit-FRB CN13, CN14, CN15, CN16 for proper connection and correct as necessary. 3 Check the connector between FRB CN1, CN3-PRCB CN7, CN9 for proper connection and correct as necessary. 4 Replace the developing unit. 5 Replace FRB. 6 Replace PRCB.
Description: Developing unit/Y new article release
The status with the new unit is not cleared after the new developing unit is set.
Remedy: 1 Reinstall developing unit. 2 Check the connector between developing unit-FRB CN13, CN14, CN15, CN16 for proper connection and correct as necessary. 3 Check the connector between FRB CN1, CN3-PRCB CN7, CN9 for proper connection and correct as necessary. 4 Replace the developing unit. 5 Replace FRB. 6 Replace PRCB.
Description: Developing unit/K new article release
The status with the new unit is not cleared after the new developing unit is set.
Remedy: 1 Reinstall developing unit. 2 Check the connector between developing unit-FRB CN13, CN14, CN15, CN16 for proper connection and correct as necessary. 3 Check the connector between FRB CN1, CN3-PRCB CN7, CN9 for proper connection and correct as necessary. 4 Replace the developing unit. 5 Replace FRB. 6 Replace PRCB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.